Dryer Exhaust Air Recirculation: Humidity and Heat Saving

Inlet and exhaust humidity and heat per kg of water of an adiabatic hot-air dryer with part of the exhaust recirculated, compared with once-through air.

Food, dairy and textileIAPWS-IF97 (water and steam)

Inputs

Examples: Illustrative half recirculationLight recirculationHeavy recirculation, hot air

Accepted: -10 to 50 °C
Accepted: 0 to 100 %
Accepted: 40 to 500 °C
Accepted: 30 to 200 °C
Accepted: 5 to 100 %
Accepted: 0.8 to 1.1 bar

Results

In an adiabatic dryer the air cools along a constant-enthalpy line, picking up water. Once-through, every kg of air is heated from ambient and thrown away still warm. Recirculating part of the warm, humid exhaust raises the humidity in the dryer but the heater then only needs to warm the mixture from a higher temperature, so the heat per kg of water falls. The limit is the exhaust humidity: too much recirculation slows drying and risks condensation in ducts and on the product. The steady state is found by iterating the mixing and drying balances.

Ambient humidity ratio16.043g/kg
Exhaust humidity, once-through47.538g/kg
Heat per kg of water, once-through3,946.8kJ/kg
Exhaust humidity with recirculation82.807g/kg
Heat per kg of water with recirculation3,251.8kJ/kg
Heat saved17.609%
Exhaust relative humidity with recirculation38.158%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative half recirculation. The inputs, in the units selected above:

InputValue
Ambient air temperature30.000 °C
Ambient relative humidity60.000 %
Air inlet temperature (after the heater)150.00 °C
Exhaust temperature70.000 °C
Share of fresh air in the heater feed50.000 %
Pressure1.0132 bar

Applying the formula below gives:

ResultValue
Ambient humidity ratio16.043 g/kg
Exhaust humidity, once-through47.538 g/kg
Heat per kg of water, once-through3,946.8 kJ/kg
Exhaust humidity with recirculation82.807 g/kg
Heat per kg of water with recirculation3,251.8 kJ/kg
Heat saved17.609 %
Exhaust relative humidity with recirculation38.158 %

Open this example in the calculator and change any input.

Formula

\(h_{in} = h_{out}, \quad x_m = f x_a + (1 - f) x_e, \quad q = \frac{h(T_{in}, x_m) - h_m}{x_e - x_m}\)

Variables

Symbol Meaning SI unit
\(T_a\) Ambient air temperature K
\(\varphi_a\) Ambient relative humidity -
\(T_{in}\) Air inlet temperature (after the heater) K
\(T_{out}\) Exhaust temperature K
\(f\) Share of fresh air in the heater feed -
\(p\) Pressure Pa
\(x_a\) Ambient humidity ratio kg/kg
\(x_{e,1}\) Exhaust humidity, once-through kg/kg
\(q_1\) Heat per kg of water, once-through J/kg
\(x_{e,2}\) Exhaust humidity with recirculation kg/kg
\(q_2\) Heat per kg of water with recirculation J/kg
\(1 - q_2/q_1\) Heat saved -
\(\varphi_{e,2}\) Exhaust relative humidity with recirculation -

Method and standards

Recirculation.

Where it is used

  • Batch and continuous convective dryers.
  • Energy audits of tea, grain, textile and chemical dryers.

Common mistakes

  • Recirculating until the exhaust is near saturation.
  • Ignoring heat losses, which recirculation does not reduce.

Assumptions and limits

  • Adiabatic dryer; humid enthalpy with constant specific heats.

References

  • Psychrometrics: humidity ratio 0.621945 p_v/(p − p_v)
  • humid enthalpy 1006 t + x(2 501 000 + 1860 t)
  • saturation pressure from IAPWS-IF97

Questions and answers

How much heat does recirculation save?

Often 15–30 %: with half the exhaust recirculated in the defaults it saves about 18 %.

What limits recirculation?

The exhaust humidity: drying slows and condensation risk rises as it approaches saturation.

What do the defaults represent?

An illustrative dryer with air heated to 150 °C, exhaust at 70 °C, ambient 30 °C and 60 % RH, half fresh air.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.