Worked example
Example: Illustrative 1 t batch at 100 mbar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Dry solids in the batch | 1,000.0 kg |
| Initial moisture (dry basis) | 40.000 % |
| Final moisture (dry basis) | 2.0000 % |
| Dryer pressure (absolute) | 10.000 kPa |
| Jacket (heating medium) temperature | 120.00 °C |
| Heated area | 10.000 m² |
| Mean overall heat transfer coefficient | 60.000 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water to remove | 380.00 kg |
| Boiling temperature at the dryer pressure | 45.808 °C |
| Heat flow | 44.515 kW |
| Drying time | 5.6721 h |
| Latent heat at the boiling temperature | 2,392.1 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(m_w = m_d(X_0 - X_1), \quad \dot Q = UA(T_j - T_b(p)), \quad t = \frac{m_w\lambda}{\dot Q}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m_d\) | Dry solids in the batch | kg |
| \(X_0\) | Initial moisture (dry basis) | - |
| \(X_1\) | Final moisture (dry basis) | - |
| \(p\) | Dryer pressure (absolute) | Pa |
| \(T_j\) | Jacket (heating medium) temperature | K |
| \(A\) | Heated area | m² |
| \(U\) | Mean overall heat transfer coefficient | W/(m²·K) |
| \(m_w\) | Water to remove | kg |
| \(T_b\) | Boiling temperature at the dryer pressure | K |
| \(\dot Q\) | Heat flow | W |
| \(t\) | Drying time | s |
| \(\lambda\) | Latent heat at the boiling temperature | J/kg |
Method and standards
Vacuum dryer.
Where it is used
- Pharmaceutical, fine chemical and food batch drying.
- Choosing vacuum level and jacket temperature.
Common mistakes
- Using the wet-product U for the whole batch.
- Forgetting solvent instead of water properties.
Assumptions and limits
- Water as the liquid; mean U over the batch.
References
- Contact drying under vacuum with IAPWS-IF97 boiling temperature
Questions and answers
At what temperature does water boil at 100 mbar?
About 46 °C.
Why does drying slow at the end?
Dry product contacts the hot wall poorly and the remaining moisture is bound, so U falls.
What do the defaults represent?
An illustrative 1 t (dry) batch dried from 40 % to 2 % (dry basis) at 100 mbar with a 120 °C jacket, 10 m² and U = 60 W/(m²·K).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.