FireCADCalc

Superheated Steam Dryer: Energy Use and Recoverable Steam

Heat input to a superheated-steam dryer and the excess steam it releases, which can be reused, compared with the heat of an air dryer, using IF97 steam properties.

Sugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)

Inputs

Examples: Illustrative 1 t/h at atmospheric pressurePressurised pulp dryer at 4 barSludge, no recovery

Accepted: 0.36 to 180,000 kg/h
Accepted: 0.01 to 100 °C
Accepted: 0.2 to 6 bar
Accepted: 100 to 400 °C
Accepted: 0 to 360,000 kg/h
Accepted: 0.5 to 4 kJ/(kg·K)
Accepted: 0 to 100 %
Accepted: 10 to 100 %

Results

In a superheated-steam dryer the drying medium is the product's own vapour recirculated and reheated. The water evaporated leaves as extra steam at the dryer pressure, so the heat input per kg of water is roughly the enthalpy rise from feed water to superheated steam. Unlike air dryers, that excess steam is not lost: condensed in a process heater or evaporator it returns most of its latent heat, so the net consumption can be a fraction of an air dryer's. The air-dryer figure uses vapour leaving at about 50 °C over the air dryer's efficiency.

Heat input to the steam loop386.85kW
Heat per kg of water2,785.3kJ/kg
Heat recovered from the excess steam0kW
Net heat per kg of water after recovery2,785.3kJ/kg
Heat per kg of water in an air dryer5,062.4kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1 t/h at atmospheric pressure. The inputs, in the units selected above:

InputValue
Water evaporated1,000.0 kg/h
Feed temperature20.000 °C
Dryer pressure (absolute)1.0132 bar
Steam outlet temperature150.00 °C
Dry solids rate1,500.0 kg/h
Specific heat of the solids1.5000 kJ/(kg·K)
Share of the excess steam's latent heat recovered70.000 %
Thermal efficiency of an air dryer for comparison55.000 %

Applying the formula below gives:

ResultValue
Heat input to the steam loop797.90 kW
Heat per kg of water2,872.4 kJ/kg
Heat recovered from the excess steam438.77 kW
Net heat per kg of water after recovery1,292.8 kJ/kg
Heat per kg of water in an air dryer4,564.1 kJ/kg

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_w\left[h_v(p, T_o) - h_l(T_f)\right] + \dot m_s c_s \Delta T_s, \quad \dot Q_r = f_r\,\dot m_w h_{fg}(p)\)

Variables

Symbol Meaning SI unit
\(\dot m_w\) Water evaporated kg/s
\(T_f\) Feed temperature K
\(p\) Dryer pressure (absolute) Pa
\(T_o\) Steam outlet temperature K
\(\dot m_s\) Dry solids rate kg/s
\(c_s\) Specific heat of the solids J/(kg·K)
\(f_r\) Share of the excess steam's latent heat recovered -
\(\eta_a\) Thermal efficiency of an air dryer for comparison -
\(\dot Q\) Heat input to the steam loop W
\(q_w\) Heat per kg of water J/kg
\(\dot Q_r\) Heat recovered from the excess steam W
\(q_{net}\) Net heat per kg of water after recovery J/kg
\(q_a\) Heat per kg of water in an air dryer J/kg

Method and standards

Superheated steam drying.

Where it is used

  • Pulp, sludge, bagasse, lignite and timber drying.
  • Integrating dryers with plant steam systems.

Common mistakes

  • Counting the excess steam as a loss.
  • Feeding cold product that condenses steam on its surface.

Assumptions and limits

  • Steady state; heat losses not included; air leakage nil.

References

  • Energy balance of superheated-steam drying with IAPWS-IF97

Questions and answers

Why can a superheated steam dryer save energy?

The evaporated water leaves as steam that can be condensed elsewhere in the plant, recovering most of its latent heat.

Does the product reach 100 °C?

Yes, at atmospheric pressure the product surface sits near the saturation temperature, which suits pulp, sludge, bagasse and coal, not heat-sensitive food.

What do the defaults represent?

An illustrative dryer evaporating 1 t/h at atmospheric pressure with steam leaving at 150 °C, 1.5 t/h of solids, 70 % of the excess steam's latent heat reused.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Mujumdar (ed.), Handbook of Industrial Drying, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.