FireCADCalc

Cost of Steam per Tonne

Cost of producing one tonne of steam from fuel, water, chemicals and power, with the fuel per tonne from the steam conditions, efficiency and calorific value.

Thermal power plantSugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Coal, 10.5 bar(a) saturated, feed 105 °C, 78 %Natural gas, 10.5 bar(a), feed 80 °C, 88 %Bagasse, 45 bar(a) / 400 °C, feed 120 °C, 68 %

Steam

Fuel

Prices (your currency)

Results

Cost of steam per tonne (your currency)807.72
Of which fuel613.72
Of which water4.0000
Of which power180.00
Fuel per tonne of steam409.15kg
Heat added per kg of steam2,698.7kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Coal, 10.5 bar(a) saturated, feed 105 °C, 78 %. The inputs, in the units selected above:

InputValue
Steam pressure (absolute)10.500 bar
Steam conditionDry saturated
Steam temperature (superheated only)250.00 °C
Feedwater temperature105.00 °C
Boiler efficiency (on GCV)78.000 %
Gross calorific value of the fuel, as fired18,600 kJ/kg
Fuel price per tonne7,000.0 -
Make-up water, tonnes per tonne of steam0.40000 -
Treated water price per tonne (m³)60.000 -
Chemicals per tonne of steam20.000 -
Auxiliary power, kWh per tonne of steam25.000 -
Electricity price per kWh8.0000 -

Applying the formula below gives:

ResultValue
Cost of steam per tonne (your currency)1,372.1
Of which fuel1,128.1
Of which water24.000
Of which power200.00
Fuel per tonne of steam161.16 kg
Heat added per kg of steam2,338.1 kJ/kg

Open this example in the calculator and change any input.

Formula

\(m_f = \frac{1000\,(h_s - h_{fw})}{\eta_1\,GCV} \qquad C_f = \frac{m_f}{1000}\,c_f \qquad C_w = x_{mu}\,c_w \qquad C_e = e\,c_e\)

\(C = C_f + C_w + c_c + C_e\)

Variables

Symbol Meaning SI unit
\(p\) steam pressure, absolute Pa
\(\text{state}\) saturated or superheated steam –
\(T_s\) steam temperature (superheated) K
\(T_{fw}\) feedwater temperature K
\(\eta_1\) boiler efficiency on GCV –
\(GCV\) gross calorific value J/kg
\(c_f\) fuel price per tonne –
\(x_{mu}\) make-up water, tonnes per tonne of steam –
\(c_w\) treated water price per tonne –
\(c_c\) chemicals per tonne of steam –
\(e\) auxiliary power, kWh per tonne of steam –
\(c_e\) electricity price per kWh –
\(C\) cost of steam per tonne –
\(C_f\) fuel cost per tonne of steam –
\(C_w\) water cost per tonne of steam –
\(C_e\) power cost per tonne of steam –
\(m_f\) fuel per tonne of steam kg
\(h_s - h_{fw}\) heat added per kg of steam J/kg

Method and standards

Fuel per tonne from the heat added per kg of steam (FireCAD's IAPWS-IF97 enthalpies) and the boiler efficiency on GCV; the other items as entered. All prices in one currency of your choice.

Where it is used

  • Pricing steam to process departments and for internal transfer.
  • Valuing steam leaks, failed traps, insulation and condensate return.
  • Comparing fuels and boilers on cost per tonne.

Common mistakes

  • Using the boiler's design efficiency instead of the measured one.
  • Leaving out make-up water and treatment, which can be 5–10 % of the cost where condensate is lost.
  • Comparing steam costs at different pressures and feedwater temperatures.

Assumptions and limits

  • Variable cost only; no capital, labour or maintenance.
  • One fuel; efficiency on GCV.
  • The fuel per tonne covers the heat from feedwater to steam only. Heat lost in the blowdown and the heating of cold make-up water before the feedwater temperature are not added; include them in the efficiency or in the feedwater temperature you enter.
  • Water price per tonne and per m³ are taken as equal.

References

  • IAPWS R7-97(2012) IF97
  • first law heat balance

Questions and answers

How do I calculate the cost of steam?

Add the fuel, water, chemicals and power for one tonne. Saturated steam at 10.5 bar(a) from feedwater at 105 °C needs 2338 MJ per tonne; at 78 % efficiency and 18.6 MJ/kg that is 161 kg of coal. With coal at 7000 a tonne, 0.4 t of water at 60, chemicals 20 and 25 kWh at 8, steam costs about 1372 per tonne.

Why is fuel most of the cost?

Fuel is usually 75–90 % of the running cost of steam. A 1 % gain in efficiency lowers the steam cost by about 1 %; leaks and lost condensate cost the full price of the steam.

What about capital and labour?

This calculator gives the variable (marginal) cost, which is what a leak, a trap or an energy project saves. Add depreciation, labour and maintenance per tonne for the full cost.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.