FireCADCalc

Pneumatic Ash or Fuel Conveying: Air Flow and Velocity

Conveying air mass and free-air flow from the solids rate and the solids loading ratio, and the air velocity in the pipe at the conveying pressure and temperature.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolAir compressor and receiver

Inputs

Examples: Fly ash dense phaseLean phase

Results

Velocity rises along the pipe as pressure falls; check the pick-up velocity at the feed end and wear at the outlet.

Conveying air1,333.3kg/h
Free air at 0 °C, 1 atm (normal; FAD at a 20 °C intake is about 7 % more)1,031.7Nm³/h
Air density in the pipe1.6688kg/m³
Air velocity in the pipe18.086m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Fly ash dense phase. The inputs, in the units selected above:

InputValue
Solids conveyed10.000 t/h
Solids loading ratio (kg solids per kg air)10.000 kg/kg
Pipe bore150.00 mm
Air pressure in the pipe (absolute)2.0000 bar
Air temperature50.000 °C

Applying the formula below gives:

ResultValue
Conveying air1,000.0 kg/h
Free air at 0 °C, 1 atm (normal; FAD at a 20 °C intake is about 7 % more)773.80 Nm³/h
Air density in the pipe2.1562 kg/m³
Air velocity in the pipe7.2903 m/s

Open this example in the calculator and change any input.

Formula

\(\dot m_a = \frac{\dot m_s}{\mu}, \quad \rho_a = \frac{pM}{RT}, \quad v = \frac{\dot m_a}{\rho_a \pi d^2/4}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) Solids conveyed kg/s
\(\mu\) Solids loading ratio (kg solids per kg air) kg/kg
\(d\) Pipe bore m
\(p\) Air pressure in the pipe (absolute) Pa
\(T\) Air temperature K
\(\dot m_a\) Conveying air kg/s
\(\dot V_n\) Free air (0 °C, 1 atm) Nm³/s
\(\rho_a\) Air density in the pipe kg/m³
\(v\) Air velocity in the pipe m/s

Method and standards

Mass balance with the solids loading ratio; air density by the ideal-gas law with the dry-air molar mass; free air at 0 °C and 101.325 kPa from the normal molar volume.

Where it is used

  • Ash handling system checks.
  • Compressor sizing.

Common mistakes

  • Free-air and actual volumes confused.

Assumptions and limits

  • Air only (solids volume ignored).
  • The free air is at 0 °C and 1 atm. Compressor makers quote free air delivery (FAD) at intake conditions: at 20 °C it is 293.15/273.15, about 7 % more; size the compressor on that.
  • The velocity is not checked against the pick-up or saltation velocity of the material: take it from the conveyor maker or test data.

References

  • Mass balance with the solids loading ratio; ideal gas with the dry-air molar mass

Questions and answers

Dense or lean phase?

High loading ratios at low velocity are dense phase; low ratios at high velocity are lean phase.

Why does velocity change along the pipe?

Air expands as pressure falls toward the silo.

Typical loading?

Lean phase a few kg per kg; dense phase tens of kg per kg.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.