Worked example
Example: Fly ash dense phase. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Solids conveyed | 10.000 t/h |
| Solids loading ratio (kg solids per kg air) | 10.000 kg/kg |
| Pipe bore | 150.00 mm |
| Air pressure in the pipe (absolute) | 2.0000 bar |
| Air temperature | 50.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Conveying air | 1,000.0 kg/h |
| Free air at 0 °C, 1 atm (normal; FAD at a 20 °C intake is about 7 % more) | 773.80 Nm³/h |
| Air density in the pipe | 2.1562 kg/m³ |
| Air velocity in the pipe | 7.2903 m/s |
Open this example in the calculator and change any input.
Formula
\(\dot m_a = \frac{\dot m_s}{\mu}, \quad \rho_a = \frac{pM}{RT}, \quad v = \frac{\dot m_a}{\rho_a \pi d^2/4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | Solids conveyed | kg/s |
| \(\mu\) | Solids loading ratio (kg solids per kg air) | kg/kg |
| \(d\) | Pipe bore | m |
| \(p\) | Air pressure in the pipe (absolute) | Pa |
| \(T\) | Air temperature | K |
| \(\dot m_a\) | Conveying air | kg/s |
| \(\dot V_n\) | Free air (0 °C, 1 atm) | Nm³/s |
| \(\rho_a\) | Air density in the pipe | kg/m³ |
| \(v\) | Air velocity in the pipe | m/s |
Method and standards
Mass balance with the solids loading ratio; air density by the ideal-gas law with the dry-air molar mass; free air at 0 °C and 101.325 kPa from the normal molar volume.
Where it is used
- Ash handling system checks.
- Compressor sizing.
Common mistakes
- Free-air and actual volumes confused.
Assumptions and limits
- Air only (solids volume ignored).
- The free air is at 0 °C and 1 atm. Compressor makers quote free air delivery (FAD) at intake conditions: at 20 °C it is 293.15/273.15, about 7 % more; size the compressor on that.
- The velocity is not checked against the pick-up or saltation velocity of the material: take it from the conveyor maker or test data.
References
- Mass balance with the solids loading ratio; ideal gas with the dry-air molar mass
Questions and answers
Dense or lean phase?
High loading ratios at low velocity are dense phase; low ratios at high velocity are lean phase.
Why does velocity change along the pipe?
Air expands as pressure falls toward the silo.
Typical loading?
Lean phase a few kg per kg; dense phase tens of kg per kg.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.