FireCADCalc

Fuel Oil Viscosity at Temperature (ASTM D341)

Kinematic viscosity of fuel oil at any temperature from two known points by the ASTM D341 (Walther) chart equation, and the heating temperature for a target viscosity.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliserFood, dairy and textileFuel oil and gas systemBurner and furnace

Inputs

Examples: Furnace oil 180 cSt at 50 °C, 30 cSt at 100 °C; at 120 °C; 15 cSt targetLSHS 500 cSt at 50 °C, 50 at 100 °C; at 130 °C; 20 cStLight diesel 6 cSt at 40 °C, 2.4 at 100 °C; at 20 °C; 4 cSt

From the burner maker; pressure-jet burners often need lower viscosity than rotary-cup or steam-atomised burners.

Results

A temperature lies outside the two known points: the result is extrapolated. Check it is above the pour point and well below the flash point.

Viscosity at the temperature wanted9.4048cSt
Oil temperature for the target viscosity62.574°C
Viscosity-temperature slope (D341)2.9635

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Furnace oil 180 cSt at 50 °C, 30 cSt at 100 °C; at 120 °C; 15 cSt target. The inputs, in the units selected above:

InputValue
Temperature of the first known point50.000 °C
Viscosity at the first point180.00 cSt
Temperature of the second known point100.00 °C
Viscosity at the second point30.000 cSt
Temperature wanted120.00 °C
Target viscosity (atomising or pumping)15.000 cSt

Applying the formula below gives:

ResultValue
Viscosity at the temperature wanted18.276 cSt
Oil temperature for the target viscosity129.13 °C
Viscosity-temperature slope (D341)2.8997

Open this example in the calculator and change any input.

Formula

\(\log\log(\nu + 0.7) = A - B\,\log T \quad (\nu\ \text{in cSt},\ T\ \text{in K})\)

\(B = \frac{Z_1 - Z_2}{\log T_2 - \log T_1},\quad Z_i = \log\log(\nu_i + 0.7) \qquad \nu_3 = 10^{10^{A - B\log T_3}} - 0.7 \qquad T_t = 10^{(A - Z_t)/B}\)

Variables

Symbol Meaning SI unit
\(T_1\), \(T_2\) temperatures of the known points K
\(\nu_1\), \(\nu_2\) viscosities at the known points m²/s (cSt in the equation)
\(T_3\) temperature wanted K
\(\nu_t\) target viscosity m²/s
\(\nu_3\) viscosity at \(T_3\) m²/s
\(T_t\) temperature for the target viscosity K
\(B\) slope of the D341 line –
\(A\) intercept of the D341 line –
\(Z\) \(\log\log(\nu + 0.7)\) –

Method and standards

The Walther equation of ASTM D341 through two measured points. Logarithms are base 10.

Where it is used

  • Setting oil heater outlet temperature for atomisation.
  • Pumping and line heating of heavy oils.
  • Comparing oils from different suppliers.

Common mistakes

  • Extrapolating far below the pour point or above the flash point.
  • Mixing kinematic (cSt) and dynamic (cP) viscosity.
  • Using Redwood seconds without converting.

Assumptions and limits

  • Simple D341 form, good above about 2 cSt; newer editions add terms for very thin oils.
  • Outside the two known temperatures the result is extrapolated (a warning appears); check against the pour point and the flash point.

References

  • ASTM D341 Viscosity–Temperature Charts for Liquid Petroleum Products (classic Walther form with the constant 0.7)

Questions and answers

How do I find fuel oil viscosity at another temperature?

From two known points on the ASTM D341 straight line. Oil at 180 cSt at 50 °C and 30 cSt at 100 °C has 18.3 cSt at 120 °C, and reaches 15 cSt at about 129 °C.

Why two points?

The D341 line has two constants; one viscosity and the oil grade are not enough. Supplier certificates usually give viscosity at 50 °C or 40 °C and 100 °C.

What viscosity does a burner need?

The burner maker states it; pressure-jet burners need thinner oil than rotary-cup or steam-atomised ones.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.