Worked example
Example: Bituminous 30 t/h, 15 % to 2 %, outlet 70 °C, air/coal 2.0. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Raw coal feed to the mill | 30.000 t/h |
| Total moisture of the raw coal | 15.000 % |
| Moisture left in the pulverised coal | 2.0000 % |
| Raw coal temperature | 30.000 °C |
| Specific heat of the dry coal | 1.2500 kJ/(kg·K) |
| Mill outlet temperature wanted | 70.000 °C |
| Primary air (dry) to coal ratio | 2.0000 kg/kg |
| Primary air humidity, kg water per kg dry air | 0.013000 kg/kg |
| Mill grinding power (enters as heat) | 150.00 kW |
| Heat lost from the mill casing and ducts | 50.000 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water evaporated in the mill | 3.9796 t/h |
| Heat taken by drying and heating the coal | 3,147.6 kW |
| Primary air flow, dry | 60.000 t/h |
| Primary air temperature needed at the mill inlet | 245.24 °C |
Open this example in the calculator and change any input.
Formula
\(w = \frac{M_{in} - M_{out}}{1 - M_{out}}, \quad \dot m_w = \dot m_c w\)
\(Q_c = \dot m_w [h_v(T_o) - h_f(T_c)] + \dot m_c (1 - M_{in}) c_c (T_o - T_c) + \dot m_c (M_{in} - w) [h_f(T_o) - h_f(T_c)]\)
\(h_a(T) = h_{da}(T) + x_a h_{v,ig}(T)\)
\(\dot m_a = r\,\dot m_c, \quad \dot m_a [h_a(T_{in}) - h_a(T_o)] + P_m - Q_l = Q_c\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_c\) | raw coal feed | kg/s |
| \(M_{in}\) | total moisture of the raw coal | - |
| \(M_{out}\) | moisture left in the pulverised coal | - |
| \(T_c\) | raw coal temperature | K |
| \(c_c\) | specific heat of the dry coal, ash included, as a constant mean value | J/(kg·K) |
| \(P_m\) | mill grinding power, entering as heat | W |
| \(Q_l\) | mill casing and duct heat loss | W |
| \(\dot m_w\) | water evaporated | kg/s |
| \(Q_c\) | heat taken by the coal side | W |
| \(\dot m_a\) | primary air flow, dry air | kg/s |
| \(T_{in}\) | primary air temperature at the mill inlet | K |
| \(r\) | primary air (dry) to coal ratio | kg/kg |
| \(h_v\) | water vapour enthalpy at T_o and 1 psia | J/kg |
| \(h_f\) | liquid water enthalpy | J/kg |
| \(h_a\) | humid air enthalpy per kg dry air: dry air plus x_a kg of ideal-gas water vapour | J/kg |
| \(x_a\) | primary air humidity, kg water vapour per kg dry air | kg/kg |
| \(h_{da}\) | dry air enthalpy | J/kg |
| \(h_{v,ig}\) | ideal-gas water vapour enthalpy | J/kg |
| \(w\) | water evaporated per kg raw coal | kg/kg |
| \(T_o\) | mill outlet temperature wanted | K |
Method and standards
A heat balance on the mill: the hot primary air gives up heat between the mill inlet and outlet temperatures; with the grinding power (which ends as heat) it evaporates the surface moisture and warms the coal and the water left in it. The evaporated water leaves as vapour (IAPWS-IF97 at 1 psia, as ASME PTC 4 treats flue gas moisture); the primary air is humid: per kg of dry air it carries x_a kg of water vapour, and its enthalpy is dry air plus that vapour as an ideal gas from NIST Shomate data, the basis ASME PTC 4 uses for moisture in air.
Where it is used
- Checking whether the air heater can dry a wetter coal.
- Setting the hot and tempering air mix for a target outlet temperature.
- Explaining mill output limits in the monsoon.
Common mistakes
- Using total moisture as the moisture removed: some stays in the pulverised coal.
- Ignoring mill casing heat losses on long PA ducts.
- Running outlet temperatures above the safe limit for high-volatile coal.
Assumptions and limits
- Steady state; tempering air is assumed already mixed into the primary air.
- The primary air flow and the air to coal ratio are on dry air; the humidity entered is carried as vapour and adds to the heat the air brings (about 2 % at 0.013 kg/kg).
- No allowance for seal air or leakage.
- The evaporated water is valued as vapour at 1 psia (the ASME PTC 4 flue-gas convention), not at the actual partial pressure in the mill; the difference is small.
- A warning appears when the inlet air would need to be above 400 °C.
References
- Mill heat balance
- IAPWS-IF97
- ASME PTC 4 (vapour at 1 psia)
Questions and answers
What primary air temperature dries coal with 15 % moisture?
In the example, 30 t/h dried to 2 % with an air to coal ratio of 2.0 and a 70 °C outlet needs air at about 245 °C at the mill inlet (primary air humidity 0.013 kg/kg).
Why does wet coal limit mill output?
The air heater can only supply so much hot air; when the drying heat needed exceeds it, the outlet temperature falls and the coal is fed slower.
Does grinding power help drying?
Yes: nearly all mill motor power ends as heat in the coal and air, reducing the air temperature needed.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.