Minimum Fluidisation Velocity (Wen and Yu)

Minimum fluidisation velocity of a bubbling or circulating fluidised bed from particle size and density and the gas temperature, by the Wen and Yu correlation.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileBoiler

Inputs

Examples: Sand 0.6 mm, 2600 kg/m³, bed 850 °CSand 1.0 mm, 2650 kg/m³, 850 °CAsh 0.3 mm, 2200 kg/m³, cold test 30 °C

Results

Air properties are used for the gas; bubbling beds run at a few times U_mf, set by the boiler design.

Minimum fluidisation velocity0.33948m/s
Archimedes number4,077.9
Reynolds number at minimum fluidisation2.3842
Gas density (air)0.31429kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Sand 0.6 mm, 2600 kg/m³, bed 850 °C. The inputs, in the units selected above:

InputValue
Mean particle diameter0.60000 mm
Particle density2,600.0 kg/m³
Gas (bed) temperature850.00 °C
Gas pressure (absolute)1.0132 bar

Applying the formula below gives:

ResultValue
Minimum fluidisation velocity0.12320 m/s
Archimedes number864.21
Reynolds number at minimum fluidisation0.51915
Gas density (air)0.31429 kg/m³

Open this example in the calculator and change any input.

Formula

\(Ar = \frac{d_p^3\,\rho_g(\rho_p - \rho_g)\,g}{\mu^2} \qquad Re_{mf} = \sqrt{33.7^2 + 0.0408\,Ar} - 33.7 \qquad U_{mf} = \frac{Re_{mf}\,\mu}{\rho_g\,d_p}\)

Variables

Symbol Meaning SI unit
\(d_p\) mean particle diameter m
\(\rho_p\) particle density kg/m³
\(T\) gas temperature K
\(p\) gas pressure Pa
\(U_{mf}\) minimum fluidisation velocity m/s
\(Ar\) Archimedes number –
\(Re_{mf}\) Reynolds number at U_mf –
\(\rho_g\) gas density kg/m³
\(\mu\) gas viscosity Pa·s
\(g\) standard gravity, 9.80665 m/s²

Method and standards

Wen and Yu (1966) correlation; air density by the ideal-gas law and viscosity from FireCAD's Sutherland–Wilke model of dry air.

Where it is used

  • AFBC and CFBC boiler design and operation.
  • Choosing bed material size.
  • Cold fluidisation tests.

Common mistakes

  • Using sieve size for irregular particles without a shape factor.
  • Using cold-air properties at bed temperature.
  • Confusing minimum fluidisation with operating velocity.

Assumptions and limits

  • Spherical-equivalent particles of one size; air as the fluidising gas (flue gas in a firing bed differs by a few per cent in density and viscosity).
  • The fluidisation regime calculator uses Grace's constants (27.2 and 0.0408) instead of Wen and Yu's 33.7 and 0.0408, so it gives a somewhat different U_mf for the same particle; both are published fits.

References

  • C.Y. Wen and Y.H. Yu (1966)
  • Air viscosity by Sutherland's law for each gas mixed by Wilke's rule
  • density by the ideal-gas law

Questions and answers

What is the minimum fluidisation velocity of bed sand?

For 0.6 mm sand of 2600 kg/m³ at 850 °C, Ar = 864 and U_mf = 0.12 m/s. Bubbling beds run at several times this.

Why is U_mf lower when hot?

Hot gas is thinner but much more viscous; for fine particles the viscosity wins, so U_mf falls as the bed heats up.

Can I check it cold?

Yes: run the same calculation at room temperature to set fluidising tests on a cold bed, then convert.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.