FireCADCalc

Fluidisation Regime Velocities: Umf, Turbulent, Transport, Slugging

Archimedes number, minimum fluidisation velocity (Grace), turbulent transition velocities, transport velocity and minimum slugging velocity of a bed (Basu ch. 2).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: Basu's example sand 300 µm at 825 °CCoarse bed 600 µm, ambient

Results

The turbulent-transition correlations (Horio and Morishita) come from small laboratory beds; treat u_c and u_k as indicative for boiler-size beds.

Archimedes number103.28
Minimum fluidisation velocity0.036718m/s
Onset of turbulent fluidisation3.9655m/s
Turbulent regime fully developed6.1856m/s
Transport velocity (Perales)6.4948m/s
Minimum slugging velocity0.13548m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Basu's example sand 300 µm at 825 °C. The inputs, in the units selected above:

InputValue
Mean particle diameter (surface-volume)0.30000 mm
Particle density2,500.0 kg/m³
Gas density0.31600 kg/m³
Gas viscosity0.045000 cP
Bed (furnace) diameter or equivalent0.20300 m

Applying the formula below gives:

ResultValue
Archimedes number103.28
Minimum fluidisation velocity0.036718 m/s
Onset of turbulent fluidisation3.9655 m/s
Turbulent regime fully developed6.1856 m/s
Transport velocity (Perales)6.4948 m/s
Minimum slugging velocity0.13548 m/s

Open this example in the calculator and change any input.

Formula

\(Ar = \frac{\rho_g(\rho_p - \rho_g)gd_p^3}{\mu^2}, \quad Re_{mf} = \sqrt{27.2^2 + 0.0408Ar} - 27.2\)

\(Re_c = 0.936Ar^{0.472}, \quad Re_k = 1.46Ar^{0.472}, \quad U_{tr} = 1.45\frac{\mu}{\rho_gd_p}Ar^{0.484}, \quad U_{sl} = U_{mf} + 0.07\sqrt{gD}\)

Variables

Symbol Meaning SI unit
\(d_p\) Mean particle diameter (surface-volume) m
\(\rho_p\) Particle density kg/m³
\(\rho_g\) Gas density kg/m³
\(\mu\) Gas viscosity Pa·s
\(D\) Bed (furnace) diameter or equivalent m
\(Ar\) Archimedes number -
\(U_{mf}\) Minimum fluidisation velocity m/s
\(u_c\) Onset of turbulent fluidisation m/s
\(u_k\) Turbulent regime fully developed m/s
\(U_{tr}\) Transport velocity (Perales) m/s
\(U_{sl}\) Minimum slugging velocity m/s

Method and standards

Correlations quoted by Basu, ch. 2.

Where it is used

  • CFB and BFB furnace design.
  • Bed material selection.

Common mistakes

  • Using mean size by mass instead of surface-volume mean.
  • Applying small-column correlations without margin.

Assumptions and limits

  • Spherical-ish particles; correlations from small beds. The turbulent-transition values are indicative for large beds, and slugging does not occur in beds wider than about a metre (notes appear).
  • Standard gravity 9.80665 m/s².

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 2
  • Eqs. (2.3) (Grace: C₁ 27.2, C₂ 0.0408)
  • (2.7) (Stewart and Davidson)
  • (2.10)–(2.11) (Horio and Morishita)
  • (2.14) (Perales et al.)

Questions and answers

Which regime do CFB boilers run in?

Fast fluidisation, above the transport velocity, typically 4–6 m/s.

Which do bubbling beds use?

1–3 m/s, above U_mf but below the turbulent transition.

Why does slugging not matter for boilers?

Basu notes commercial beds are too wide for bubbles to grow to the bed diameter.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.