External Fluid-Bed Heat Exchanger Duty

Heat absorbed by tubes in an external fluidised-bed heat exchanger from tube coefficient, area and LMTD (Basu Eq. 3.24), and the solids flow it needs.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 800 m2 superheater FBHEEvaporator FBHE

Results

FBHEs let the operator move heat between furnace and superheaters by controlling the solids flow through them.

Mean temperature difference, well-mixed bed at the solids outlet temperature222.71K
Duty53.451MW
Solids flow for the temperature drop1,257.7t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 800 m2 superheater FBHE. The inputs, in the units selected above:

InputValue
Overall heat transfer coefficient of the tubes300.00 W/(m²·K)
Tube outside area800.00 m²
Solids in870.00 °C
Solids out700.00 °C
Steam or water in400.00 °C
Steam or water out540.00 °C
Solids specific heat0.90000 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Mean temperature difference, well-mixed bed at the solids outlet temperature222.71 K
Duty53.451 MW
Solids flow for the temperature drop1,257.7 t/h

Open this example in the calculator and change any input.

Formula

\(\Delta T_m = \frac{(T_{s,out} - T_{w,in}) - (T_{s,out} - T_{w,out})}{\ln\frac{T_{s,out} - T_{w,in}}{T_{s,out} - T_{w,out}}}, \quad Q = H_{tube}A_0\,\Delta T_m, \quad \dot m_s = \frac{Q}{c_s(T_{s,in} - T_{s,out})}\)

Variables

Symbol Meaning SI unit
\(H_{tube}\) Overall heat transfer coefficient of the tubes W/(m²·K)
\(A_0\) Tube outside area m²
\(T_{s,in}\) Solids in K
\(T_{s,out}\) Solids out, which is also the temperature of the well-mixed bed K
\(T_{w,in}\) Steam or water in K
\(T_{w,out}\) Steam or water out K
\(c_s\) Solids specific heat J/(kg·K)
\(\Delta T_m\) Mean temperature difference between the bed and the steam or water K
\(Q_{FBHE}\) Duty W
\(\dot m_s\) Solids flow for the temperature drop kg/s

Method and standards

Basu's Eq. (3.24), Q = H_tube A₀ ΔT, with a solids heat balance. The FBHE is a bubbling bed, which is well mixed: the whole bed, and the solids leaving it, are at one temperature, T_s,out. The steam or water in the tubes heats from T_w,in to T_w,out against that constant bed temperature, so the mean difference is the log mean of (T_s,out − T_w,in) and (T_s,out − T_w,out).

Where it is used

  • CFB loop design.

Common mistakes

  • Using furnace wall coefficients for immersed tubes.
  • Using the counter-flow LMTD with the solids inlet temperature: a well-mixed bed never sees the solids inlet temperature at the tubes, and that LMTD overstates the duty.

Assumptions and limits

  • Well-mixed bed at the solids outlet temperature. A bed divided into compartments in series comes closer to counter-flow and absorbs somewhat more.
  • An evaporator (water in and out at the same saturation temperature) is accepted.
  • The bed must be hotter than the steam or water leaving the tubes.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 3
  • Eq. (3.24): Q = H_tube A₀ LMTD

Questions and answers

Why an external heat exchanger?

To absorb heat outside the furnace where bed temperature and heat absorption can be controlled independently.

Is the solids side counter-current?

No: a bubbling FBHE is well mixed, so the tubes see one bed temperature, the solids outlet temperature, and the calculation uses that.

What coefficients apply?

300–600 W/m²·K for immersed tubes in a bubbling FBHE.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.