Worked example
Example: 90 % in a 30 s cook, 6 mm coal. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fraction of volatiles released | 90.000 % |
| Time for complete devolatilisation | 30.000 s |
| Pillai constant a (s per mm^p) | 5.0000 - |
| Exponent p | 1.0000 - |
| Coal particle diameter | 6.0000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Time to release the fraction x | 16.610 s |
| Devolatilisation and volatile combustion time | 30.000 s |
Open this example in the calculator and change any input.
Formula
\(\frac{t}{\tau_C} = 1 - 3(1 - x)^{2/3} + 2(1 - x), \quad t_v = a\,d_v^{\,p}\ (d_v\ \text{in mm})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x\) | Fraction of volatiles released | - |
| \(\tau_C\) | Time for complete devolatilisation | s |
| \(a\) | Pillai constant a (s per mm^p) | - |
| \(p\) | Exponent p | - |
| \(d_v\) | Coal particle diameter | m |
| \(t\) | Time to release the fraction x | s |
| \(t_v\) | Devolatilisation and volatile combustion time | s |
Method and standards
Shrinking-core relation and Pillai's empirical fit.
Where it is used
- Fuel size and feed point design.
Common mistakes
- Using constants from another coal or temperature.
Assumptions and limits
- Constants from tests. The calculator does not scale them: \(\tau_C\) grows roughly with the square of particle size and \(a\) falls steeply with temperature (about \(T^{-3.8}\)), so enter values measured at your size and bed temperature.
- The two outputs come from separate correlations: \(t\) from the \(\tau_C\) you enter and \(t_v\) from \(a\), \(p\) and \(d_v\). They are not linked and can disagree.
References
- Basu
- Circulating Fluidized Bed Boilers: Design
- Operation and Maintenance (Springer, 2015)
- ch. 4
- Eqs. (4.3) (La Nauze 1985) and (4.4) (Pillai 1981)
Questions and answers
Why does devolatilisation matter?
Volatiles released low in the bed burn there; large coal releases them higher, shifting heat release up the furnace.
What exponent p is typical?
Basu quotes 0.32 to 1.8.
Where do τ_C and a come from?
Tests on the coal at bed temperature; a falls steeply with temperature (∝ T⁻³·⁸).