Worked example
Example: Basu's example: 30 kg/m2 s at 825 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Solids circulation rate | 30.000 kg/(m²·s) |
| Particle terminal velocity | 2.7220 m/s |
| Particle density | 2,500.0 kg/m³ |
| Gas density | 0.31600 kg/m³ |
| Equivalent column diameter | 0.20300 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Voidage at choking | 99.760 % |
| Slip at choking | 5.0015 m/s |
| Choking velocity | 7.7050 m/s |
Open this example in the calculator and change any input.
Formula
\(\frac{U_{ch}}{\varepsilon_c} - U_t = \left[\frac{2gD(\varepsilon_c^{-4.7} - 1)}{6.81\times10^5}\left(\frac{\rho_p}{\rho_g}\right)^{2.2}\right]^{0.5}, \quad G_s = \left(\frac{U_{ch}}{\varepsilon_c} - U_t\right)(1 - \varepsilon_c)\rho_p\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(G_s\) | Solids circulation rate | kg/(m²·s) |
| \(U_t\) | Particle terminal velocity | m/s |
| \(\rho_p\) | Particle density | kg/m³ |
| \(\rho_g\) | Gas density | kg/m³ |
| \(D\) | Equivalent column diameter | m |
| \(\varepsilon_c\) | Voidage at choking | - |
| \(U_{ch}/\varepsilon_c - U_t\) | Slip at choking | m/s |
| \(U_{ch}\) | Choking velocity | m/s |
Method and standards
Yang's correlation solved by bisection on ε_c between 0.5 and 1; a choking voidage below 0.5 is reported as no solution. Standard gravity 9.80665 m/s².
Where it is used
- CFB riser design checks.
Common mistakes
- Extrapolating far beyond small-column data.
- Using bed-average terminal velocity for a wide size range.
Assumptions and limits
- Group A data base from columns under 0.3 m; first approximation for boilers (a warning appears above 0.3 m, where \(U_{ch}\) is extrapolated with \(\sqrt{D}\)).
References
- Basu
- Circulating Fluidized Bed Boilers: Design
- Operation and Maintenance (Springer, 2015)
- ch. 2
- Eqs. (2.12) and (2.13) (Yang 1983) and the worked example of section 2.2
Questions and answers
What is choking?
The velocity below which a column can no longer carry the solids fed to it in dilute flow; the bed collapses into a dense suspension.
Why does circulation rate matter?
More solids need a higher gas velocity to stay in dilute transport.
What does Basu's example give?
A 0.203 m column at 825 °C with 30 kg/m²·s: U_ch ≈ 7.7 m/s, ε_c ≈ 0.9976.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.