Worked example
Example: 15 × 8 m, 30 m water-cooled, 63.5/88.9 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Furnace width | 15.000 m |
| Furnace breadth (depth) | 8.0000 m |
| Water-cooled height | 30.000 m |
| Tube outer diameter | 63.500 mm |
| Tube pitch | 88.900 mm |
| Heat transfer coefficient on the projected area | 180.00 W/(m²·K) |
| Bed temperature | 850.00 °C |
| Saturation temperature at drum pressure | 320.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Actual-to-projected area ratio | 1.4077 |
| Projected wall area | 1,380.0 m² |
| Actual heat-transfer area | 1,942.6 m² |
| Wall temperature (T_sat + 25 °C) | 345.00 °C |
| Heat absorbed by the walls | 125.44 MW |
Open this example in the calculator and change any input.
Formula
\(A_x = \frac{\pi D/2 + p - D}{p}, \quad A_w = 2(W + B)L, \quad A_{actual} = A_xA_w, \quad Q_w = A_wU_h(T_b - T_{wall}), \quad T_{wall} = T_{sat} + 25\ \text{K}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Furnace width | m |
| \(B\) | Furnace breadth (depth) | m |
| \(L\) | Water-cooled height | m |
| \(D\) | Tube outer diameter | m |
| \(p\) | Tube pitch | m |
| \(U_h\) | Heat transfer coefficient on the projected area | W/(m²·K) |
| \(T_b\) | Bed temperature | K |
| \(T_{sat}\) | Saturation temperature at drum pressure | K |
| \(A_x\) | Actual-to-projected area ratio | - |
| \(A_w\) | Projected wall area | m² |
| \(A_{actual}\) | Actual heat-transfer area | m² |
| \(T_{wall}\) | Wall temperature (T_sat + 25 °C) | K |
| \(Q_w\) | Heat absorbed by the walls | W |
Method and standards
Basu's design equations.
Where it is used
- CFB furnace surface sizing.
Common mistakes
- Including refractory-lined walls in L.
- Mixing projected-area and actual-area coefficients.
Assumptions and limits
- Roof and exit areas taken as equal (Basu).
- One average coefficient and bed temperature over the whole water-cooled height. In a CFB the coefficient falls strongly with suspension density up the furnace; use a height-averaged \(U_h\) or split the furnace into zones.
- \(T_{sat}\) is entered directly; take it at the drum pressure from the saturation calculator.
References
- Basu
- Circulating Fluidized Bed Boilers: Design
- Operation and Maintenance (Springer, 2015)
- ch. 6
- Eqs. (6.14)–(6.17) and ch. 10
- Eq. (10.1) (evaporator wall at T_sat + 25 °C)
Questions and answers
What is A_x?
Actual tube-and-fin surface facing the furnace per unit projected area: half the tube circumference plus the fin, per pitch.
Which area goes with which coefficient?
Use the projected area with a coefficient based on it (U_h), or the actual area with a true local coefficient (U_c).
Why T_sat + 25 °C?
Boiling inside keeps the tube close to saturation; 25 K covers the tube wall and scale.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.