Worked example
Example: 680 mmHg vacuum, 760 mmHg barometer, CW 32 to 41 °C, hotwell 44 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vacuum gauge reading (below the barometer) | 680.00 mmHg |
| Barometric pressure | 760.00 mmHg |
| Cooling water inlet temperature | 32.000 °C |
| Cooling water outlet temperature | 41.000 °C |
| Condensate (hotwell) temperature | 44.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Absolute condenser pressure | 10.666 kPa |
| Saturation temperature | 47.074 °C |
| Terminal temperature difference | 6.0740 K |
| Initial temperature difference | 15.074 K |
| Cooling water temperature rise | 9.0000 K |
| Condensate subcooling | 3.0740 K |
| Vacuum efficiency | 93.883 % |
| Condenser (cooling water) efficiency | 59.705 % |
Open this example in the calculator and change any input.
Formula
\(p_c = p_{atm} - p_{vac} \qquad T_{sat} = T_{sat}(p_c) \qquad TTD = T_{sat} - T_{cw,2} \qquad ITD = T_{sat} - T_{cw,1}\)
\(\eta_{vac} = \frac{p_{vac}}{p_{atm} - p_{sat}(T_{cw,1})} \qquad \eta_c = \frac{T_{cw,2} - T_{cw,1}}{T_{sat} - T_{cw,1}} \qquad \Delta T_{sub} = T_{sat} - T_{hw}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_{vac}\) | vacuum gauge reading | Pa |
| \(p_{atm}\) | barometric pressure | Pa |
| \(T_{cw,1}\) | cooling water inlet temperature | K |
| \(T_{cw,2}\) | cooling water outlet temperature | K |
| \(T_{hw}\) | hotwell (condensate) temperature | K |
| \(p_c\) | absolute condenser pressure | Pa |
| \(T_{sat}\) | saturation temperature | K |
| \(TTD\) | terminal temperature difference | K |
| \(ITD\) | initial temperature difference | K |
| \(\Delta T_{cw}\) | cooling water rise, \(T_{cw,2} - T_{cw,1}\) | K |
| \(\Delta T_{sub}\) | condensate subcooling | K |
| \(\eta_{vac}\) | vacuum efficiency | – |
| \(\eta_c\) | condenser efficiency | – |
| \(p_{sat}\) | saturation pressure of water | Pa |
Method and standards
Saturation properties by FireCAD's IAPWS-IF97; TTD and ITD as used in the HEI condenser standards; vacuum and condenser efficiencies as defined in steam-plant practice (the usual examination definitions; no single standard governs them). The vacuum is a pressure difference below the barometer, so it is entered in mmHg, kPa or similar, never as a gauge pressure.
Where it is used
- Daily condenser monitoring in power and cogeneration plants.
- Troubleshooting poor vacuum: air leaks, fouling, low cooling water flow.
- Hill and high-altitude sites, where the barometer is well below 760 mmHg.
Common mistakes
- Taking 760 mmHg as the barometer at every site: at 600 m it is about 710 mmHg.
- Treating a vacuum reading as absolute pressure.
- Ignoring subcooling: it wastes heat and lets oxygen dissolve in the condensate.
Assumptions and limits
- Pure steam saturated at condenser pressure (air partial pressure neglected).
- The 10 K TTD warning is a FireCAD rule of thumb; a hotwell above saturation is flagged as a reading error.
References
- IAPWS R7-97(2012) IF97
- HEI Standards for Steam Surface Condensers (TTD and ITD terms)
Questions and answers
How do I convert condenser vacuum to absolute pressure?
Subtract the vacuum from the barometer. 680 mmHg vacuum with a 760 mmHg barometer leaves 80 mmHg, 10.7 kPa absolute, where steam condenses at 47.0 °C.
What is vacuum efficiency?
Actual vacuum over the best vacuum the cooling water could give, which is the barometer less the saturation pressure at the cooling water inlet temperature. In this example it is 93.9 %; air leaks and fouling lower it.
What TTD is normal?
About 3–6 K for a clean, air-tight condenser. A rising TTD at the same load means fouled tubes, air in the condenser or less cooling water.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.