Condenser Surface Area from LMTD

Tube surface area of a steam surface condenser from the heat load, overall heat transfer coefficient, condenser pressure and cooling water temperatures (LMTD).

Thermal power plantSugar mill and cogenerationChemical and fertiliserPulp and paperIAPWS-IF97 (water and steam)Condenser and cooling tower

Inputs

Examples: 25 MW duty, U 3000 W/(m²·K), 0.1 bar(a), CW 32 to 41 °C9 MW, U 2500, 0.12 bar(a), CW 30 to 40 °C250 MW, U 3200, 0.085 bar(a), CW 33 to 42 °C

From the tube maker, the HEI standard or plant data; typical 2500–3500 W/(m²·K) for clean admiralty or stainless tubes at 2 m/s, times a cleanliness factor of about 0.85.

Results

Tube surface area (on the basis of U, usually outside)260.45m²
Log mean temperature difference13.822K
Terminal temperature difference9.4198K
Initial temperature difference19.420K
Saturation temperature49.420°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 25 MW duty, U 3000 W/(m²·K), 0.1 bar(a), CW 32 to 41 °C. The inputs, in the units selected above:

InputValue
Condenser heat load25.000 MW
Overall heat transfer coefficient (clean × cleanliness)3,000.0 W/(m²·K)
Condenser pressure (absolute)10.000 kPa
Cooling water inlet temperature32.000 °C
Cooling water outlet temperature41.000 °C

Applying the formula below gives:

ResultValue
Tube surface area (on the basis of U, usually outside)976.88 m²
Log mean temperature difference8.5306 K
Terminal temperature difference4.8075 K
Initial temperature difference13.808 K
Saturation temperature45.808 °C

Open this example in the calculator and change any input.

Formula

\(LMTD = \frac{T_{cw,2} - T_{cw,1}}{\ln\left(ITD/TTD\right)} \qquad ITD = T_{sat} - T_{cw,1} \qquad TTD = T_{sat} - T_{cw,2} \qquad A = \frac{\dot Q}{U \cdot LMTD} \qquad T_{sat} = T_{sat}(p_c)\ \text{(IAPWS-IF97)}\)

Variables

Symbol Meaning SI unit
\(\dot Q\) condenser heat load W
\(U\) overall heat transfer coefficient W/(m²·K)
\(p_c\) condenser pressure, absolute Pa
\(T_{cw,1}\) cooling water inlet temperature K
\(T_{cw,2}\) cooling water outlet temperature K
\(A\) tube surface area m²
\(LMTD\) log mean temperature difference K
\(TTD\) terminal temperature difference K
\(ITD\) initial temperature difference K
\(T_{sat}\) saturation temperature at \(p_c\) K

Method and standards

LMTD method with the steam side at constant saturation temperature (FireCAD IAPWS-IF97); U entered by you.

Where it is used

  • First sizing of surface condensers for turbines.
  • Checking whether an existing condenser can take a higher load.
  • Back-calculating U from plant data to track fouling (with the heat load and LMTD from readings).

Common mistakes

  • Using a clean-tube U without a cleanliness factor.
  • Taking inside instead of outside tube area as the basis of U.
  • Ignoring the air-cooling zone, which transfers heat poorly.

Assumptions and limits

  • Uniform U; steam at saturation over the whole surface; no subcooling zone.
  • The area is on the same basis as U: the outside tube surface, as HEI uses, when U is referred to the outside.
  • The heat load is entered directly and not checked against the cooling water flow and range; use the condenser heat load calculator for that.

References

  • IAPWS R7-97(2012) IF97
  • LMTD method for a condensing stream

Questions and answers

How do I size a condenser?

Divide the heat load by U times the LMTD. 25 MW at 0.1 bar(a) (45.8 °C) with cooling water from 32 to 41 °C has an LMTD of 8.5 K; with U = 3000 W/(m²·K) the condenser needs 977 m².

Where does U come from?

From the HEI standard's method, the tube maker or plant data; it depends on tube material and gauge, water velocity, water temperature and a cleanliness factor. This calculator takes it as an input.

Why is the LMTD simple for a condenser?

The steam side stays at saturation temperature, so flow arrangement does not matter: LMTD = range / ln(ITD/TTD).

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.