FireCADCalc

Juice, Syrup and Molasses Pipe Flow (Hugot)

Velocity, Reynolds number, friction factor (Hugot eqns 45.10–45.13) and head loss of a sugar product in a pipe, with impure-solution viscosity from purity (45.9).

Sugar mill and cogenerationPump

Inputs

Examples: Hugot example 2: 5 L/s juice, 40 mmMolasses, laminarWater in rusted pipe

Hugot Table 45.1 (pure sucrose); measure for impure products where possible.

Results

Hugot's normal velocities (m/s, suction/delivery): water 1–1.25/1.25–2.5; juice 1–1.2/1.2–2; syrup 0.5–1/0.75–1.25; molasses 0.25–0.5/0.5–0.75; massecuite 0.1–0.2/0.15–0.3.

Kinematic viscosity of the product5.0000e-04m²/s
Velocity0.38197m/s
Reynolds number76.394
Friction factor0.83776
Head loss per metre0.062320
Head loss3.1160m
Pressure drop43.392kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example 2: 5 L/s juice, 40 mm. The inputs, in the units selected above:

InputValue
Flow5.0000 L/s
Pipe inside diameter40.000 mm
Pipe length20.000 m
Kinematic viscosity of the pure solution1.1000e-06 m²/s
Purity100.00 %
Density1,080.0 kg/m³
PipeSmooth

Applying the formula below gives:

ResultValue
Kinematic viscosity of the product1.1000e-06 m²/s
Velocity3.9789 m/s
Reynolds number144,686
Friction factor0.016424
Head loss per metre0.33143
Head loss6.6287 m
Pressure drop70.205 kPa

Open this example in the calculator and change any input.

Formula

\(U = \frac{4Q}{\pi D^2}, \quad R = \frac{UD}{\nu}, \quad \lambda = \frac{64}{R}\ (R < 2320), \quad \lambda = \frac{1}{\sqrt[4]{100R}}\ (R < 10^5), \quad \lambda = 0.0032 + \frac{0.221}{R^{0.237}}\)

\(\lambda = 0.01\left(\frac{A}{D}\right)^{0.314}\ (\text{rough pipes},\ R > 10^5), \quad j = \frac{\lambda}{D}\frac{U^2}{2g}\)

\(\nu = \frac{\nu_0}{p}\ (\text{impure solution, Hugot eqn 45.9})\)

Variables

Symbol Meaning SI unit
\(Q\) Flow m³/s
\(D\) Pipe inside diameter m
\(L\) Pipe length m
\(\nu_0\) Kinematic viscosity of the pure solution m²/s
\(p\) Purity -
\(\rho\) Density kg/m³
\(\text{pipe}\) Pipe -
\(\nu\) Kinematic viscosity of the product m²/s
\(U\) Velocity m/s
\(R\) Reynolds number -
\(\lambda\) Friction factor -
\(j\) Head loss per metre -
\(J\) Head loss m
\(\Delta p\) Pressure drop Pa

Method and standards

Hugot's flow formulae.

Where it is used

  • Sizing juice, syrup and molasses lines.
  • Checking pump heads.

Common mistakes

  • Using pure-sucrose viscosity for molasses.
  • Ignoring temperature effects on viscosity.

Assumptions and limits

  • Newtonian flow; massecuites are not Newtonian.
  • Rough pipes: Hugot's rough law (45.13) holds at very high Reynolds numbers (10⁵–10⁶, by roughness). Below 10⁵ the page uses the smooth law and shows the rough value in a note; the true value lies between them.
  • A is Hugot's roughness coefficient "having the dimension of length" (1.5, 2.5 and 5 m as printed), not a physical roughness height.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 45
  • eqns 45.1–45.13 and Table 45.2
  • pp. 1115–1123

Questions and answers

Why divide viscosity by purity?

Hugot's rough rule: impurities raise viscosity; a juice of 85 purity is about 1/0.85 times as viscous as pure sucrose solution.

Which friction law?

Laminar 64/R; smooth pipes Hugot's two turbulent laws; rough pipes at high R his (A/D)^0.314 law.

Hugot's example?

5 L/s of juice in a 40 mm pipe: 3.98 m/s, R = 144 690, λ = 0.0164, 0.33 m head per metre.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.