Worked example
Example: Hugot example: 100 TCH. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 100.00 t/h |
| Bagasse per tonne cane | 285.00 kg/t |
| Bagasse moisture | 48.000 % |
| Sugar in bagasse | 2.0000 % |
| Air factor | 1.4000 - |
| Flue gas temperature | 200.00 °C |
| Boiler factors | 91.267 % |
| Live steam pressure (absolute) | 28.439 bar |
| Live steam temperature | 380.00 °C |
| Feed water temperature | 90.000 °C |
| Electric load per t cane/h | 18.600 kWh/t |
| Motors and lines, to alternator terminals | 82.450 % |
| Turbo-generator steam rate | 11.000 kg/kWh |
| Turbine-driven load (mills, shredder) per t cane/h | 13.300 kWh/t |
| Drive turbine steam rate | 13.500 kg/kWh |
| Exhaust recovered from the turbines | 95.000 % |
| Process steam incl. losses per tonne cane | 450.00 kg/t |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam per kg bagasse | 2.1865 |
| Steam available from bagasse per tonne cane | 623.16 kg/t |
| Steam to the turbo-generator per tonne cane | 248.15 kg/t |
| Steam to drive turbines per tonne cane | 179.55 kg/t |
| Exhaust available per tonne cane | 406.32 kg/t |
| Live steam make-up to process per tonne cane | 43.685 kg/t |
| Exhaust surplus per tonne cane | 0 kg/t |
| Live steam needed per tonne cane | 471.39 kg/t |
| Bagasse surplus | 24.355 % |
| Live steam | 47.139 t/h |
Open this example in the calculator and change any input.
Formula
\(\frac SB = \frac{M_v}{h_s - h_f}, \quad S_g = \frac{P_e}{\eta_g}SR_g, \quad S_t = P_tSR_t, \quad E = x_e(S_g + S_t)\)
\(M = \max(0, S_p - E), \quad S_l = S_g + S_t + M, \quad \sigma = \frac{BS/B - S_l}{BS/B}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(B\) | Bagasse per tonne cane | kg/kg |
| \(w\) | Bagasse moisture | - |
| \(s\) | Sugar in bagasse | - |
| \(m\) | Air factor | - |
| \(t\) | Flue gas temperature | K |
| \(\alpha\beta\eta\) | Boiler factors | - |
| \(p_s\) | Live steam pressure (absolute) | Pa |
| \(T_s\) | Live steam temperature | K |
| \(t_f\) | Feed water temperature | K |
| \(P_e\) | Electric load per t cane/h | J/kg |
| \(\eta_g\) | Motors and lines, to alternator terminals | - |
| \(SR_g\) | Turbo-generator steam rate | kg/J |
| \(P_t\) | Turbine-driven load (mills, shredder) per t cane/h | J/kg |
| \(SR_t\) | Drive turbine steam rate | kg/J |
| \(x_e\) | Exhaust recovered from the turbines | - |
| \(S_p\) | Process steam incl. losses per tonne cane | kg/kg |
| \(S/B\) | Steam per kg bagasse | - |
| \(S_a\) | Steam available from bagasse per tonne cane | kg/kg |
| \(S_g\) | Steam to the turbo-generator per tonne cane | kg/kg |
| \(S_t\) | Steam to drive turbines per tonne cane | kg/kg |
| \(E\) | Exhaust available per tonne cane | kg/kg |
| \(M\) | Live steam make-up to process per tonne cane | kg/kg |
| \(X\) | Exhaust surplus per tonne cane | kg/kg |
| \(S_l\) | Live steam needed per tonne cane | kg/kg |
| \(\sigma\) | Bagasse surplus | - |
| \(\dot m_s\) | Live steam | kg/s |
Method and standards
Hugot's steam balance structure.
Where it is used
- Steam and power planning.
- Judging electrification and cogeneration.
Common mistakes
- Counting exhaust losses twice.
- Using the boiler rating instead of the bagasse available.
Assumptions and limits
- Steady crush; all exhaust used in process.
- Live steam must be superheated. Make-up to process is counted 1:1 (no desuperheating water, no blowdown). A negative bagasse surplus is a deficit and is flagged.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 41
- steam balance example
- pp. 1012–1016
- with eqns 41.25
- 41.48 and 41.50
- Steam and feed enthalpies from IAPWS-IF97
Questions and answers
What is make-up?
Live steam reduced into the exhaust main because the turbines do not exhaust enough for the process.
Why does electrification change the balance?
A turbo-generator and motors use less steam than many small drive turbines, so less exhaust is made; more make-up or more bleeding may follow.
Is surplus bagasse good?
It is fuel for the off-season or for export power; a deficit means buying fuel.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.