FireCADCalc

Sugar Factory Steam Balance (Hugot's Method)

Steam from bagasse, live steam to turbines and turbo-generator, exhaust, process make-up and surplus bagasse per tonne cane by Hugot's method.

Sugar mill and cogenerationIAPWS-IF97 (water and steam)BoilerSteam turbine

Inputs

Examples: Hugot example: 100 TCHElectrified mills

Hugot: 0.85 × 0.97.

Results

Live steam make-up to process is counted kilogram for kilogram, without desuperheating water or boiler blowdown.

Hugot's example (100 t/h, 285 kg bagasse/t, 28 kg/cm² g 380 °C): 624 kg steam/t available, 427 to the prime movers, 406 exhaust, 450 needed, 44 make-up, 471 live and about 24.5 % bagasse surplus.

Steam per kg bagasse2.1457
Steam available from bagasse per tonne cane622.25kg/t
Steam to the turbo-generator per tonne cane264.71kg/t
Steam to drive turbines per tonne cane36.000kg/t
Exhaust available per tonne cane285.67kg/t
Live steam make-up to process per tonne cane134.33kg/t
Exhaust surplus per tonne cane0kg/t
Live steam needed per tonne cane435.04kg/t
Bagasse surplus30.087%
Live steam87.007t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example: 100 TCH. The inputs, in the units selected above:

InputValue
Crushing rate100.00 t/h
Bagasse per tonne cane285.00 kg/t
Bagasse moisture48.000 %
Sugar in bagasse2.0000 %
Air factor1.4000 -
Flue gas temperature200.00 °C
Boiler factors91.267 %
Live steam pressure (absolute)28.439 bar
Live steam temperature380.00 °C
Feed water temperature90.000 °C
Electric load per t cane/h18.600 kWh/t
Motors and lines, to alternator terminals82.450 %
Turbo-generator steam rate11.000 kg/kWh
Turbine-driven load (mills, shredder) per t cane/h13.300 kWh/t
Drive turbine steam rate13.500 kg/kWh
Exhaust recovered from the turbines95.000 %
Process steam incl. losses per tonne cane450.00 kg/t

Applying the formula below gives:

ResultValue
Steam per kg bagasse2.1865
Steam available from bagasse per tonne cane623.16 kg/t
Steam to the turbo-generator per tonne cane248.15 kg/t
Steam to drive turbines per tonne cane179.55 kg/t
Exhaust available per tonne cane406.32 kg/t
Live steam make-up to process per tonne cane43.685 kg/t
Exhaust surplus per tonne cane0 kg/t
Live steam needed per tonne cane471.39 kg/t
Bagasse surplus24.355 %
Live steam47.139 t/h

Open this example in the calculator and change any input.

Formula

\(\frac SB = \frac{M_v}{h_s - h_f}, \quad S_g = \frac{P_e}{\eta_g}SR_g, \quad S_t = P_tSR_t, \quad E = x_e(S_g + S_t)\)

\(M = \max(0, S_p - E), \quad S_l = S_g + S_t + M, \quad \sigma = \frac{BS/B - S_l}{BS/B}\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(B\) Bagasse per tonne cane kg/kg
\(w\) Bagasse moisture -
\(s\) Sugar in bagasse -
\(m\) Air factor -
\(t\) Flue gas temperature K
\(\alpha\beta\eta\) Boiler factors -
\(p_s\) Live steam pressure (absolute) Pa
\(T_s\) Live steam temperature K
\(t_f\) Feed water temperature K
\(P_e\) Electric load per t cane/h J/kg
\(\eta_g\) Motors and lines, to alternator terminals -
\(SR_g\) Turbo-generator steam rate kg/J
\(P_t\) Turbine-driven load (mills, shredder) per t cane/h J/kg
\(SR_t\) Drive turbine steam rate kg/J
\(x_e\) Exhaust recovered from the turbines -
\(S_p\) Process steam incl. losses per tonne cane kg/kg
\(S/B\) Steam per kg bagasse -
\(S_a\) Steam available from bagasse per tonne cane kg/kg
\(S_g\) Steam to the turbo-generator per tonne cane kg/kg
\(S_t\) Steam to drive turbines per tonne cane kg/kg
\(E\) Exhaust available per tonne cane kg/kg
\(M\) Live steam make-up to process per tonne cane kg/kg
\(X\) Exhaust surplus per tonne cane kg/kg
\(S_l\) Live steam needed per tonne cane kg/kg
\(\sigma\) Bagasse surplus -
\(\dot m_s\) Live steam kg/s

Method and standards

Hugot's steam balance structure.

Where it is used

  • Steam and power planning.
  • Judging electrification and cogeneration.

Common mistakes

  • Counting exhaust losses twice.
  • Using the boiler rating instead of the bagasse available.

Assumptions and limits

  • Steady crush; all exhaust used in process.
  • Live steam must be superheated. Make-up to process is counted 1:1 (no desuperheating water, no blowdown). A negative bagasse surplus is a deficit and is flagged.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 41
  • steam balance example
  • pp. 1012–1016
  • with eqns 41.25
  • 41.48 and 41.50
  • Steam and feed enthalpies from IAPWS-IF97

Questions and answers

What is make-up?

Live steam reduced into the exhaust main because the turbines do not exhaust enough for the process.

Why does electrification change the balance?

A turbo-generator and motors use less steam than many small drive turbines, so less exhaust is made; more make-up or more bleeding may follow.

Is surplus bagasse good?

It is fuel for the off-season or for export power; a deficit means buying fuel.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.