Worked example
Example: 6 lakh t season. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Cane crushed in the season | 600,000 t |
| Trash (dry matter) % cane | 12.000 % |
| Share of trash recovered | 40.000 % |
| Trash moisture as delivered | 15.000 % |
| Dry trash GCV | 17.500 MJ/kg |
| Bagasse GCV (as fired) | 9.6000 MJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dry trash recovered | 28,800 t |
| Trash as delivered | 33,882 t |
| Energy (gross) | 504,000 GJ |
| Bagasse equivalent | 52,500 t |
Open this example in the calculator and change any input.
Formula
\(M_d = C_s f_t r, \quad E = M_d GCV_d, \quad M_b = \frac{E}{GCV_b}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_s\) | Cane crushed in the season | kg |
| \(f_t\) | Trash (dry matter) % cane | - |
| \(r\) | Share of trash recovered | - |
| \(w\) | Trash moisture as delivered | - |
| \(GCV_d\) | Dry trash GCV | J/kg |
| \(GCV_b\) | Bagasse GCV (as fired) | J/kg |
| \(M_d\) | Dry trash recovered | kg |
| \(M_w\) | Trash as delivered | kg |
| \(E\) | Energy (gross) | J |
| \(M_b\) | Bagasse equivalent | kg |
Method and standards
Mass balance on the dry trash recovered, its gross energy from the dry GCV, and the as-fired bagasse with the same gross heat.
Where it is used
- Off-season fuel planning.
- Cogeneration expansion.
Common mistakes
- Trash % on wet basis used as dry.
Assumptions and limits
- Season totals.
- The bagasse equivalent is on gross heat: the trash moisture as delivered and the different boiler efficiencies on trash and bagasse (moisture, ash) are not counted. On a net or useful-heat basis wet trash replaces less bagasse.
References
- Mass and energy balance on dry matter; GCV of dry trash by laboratory test
Questions and answers
How much trash is there?
Tops and leaves are roughly 10–15 % of cane on dry basis; only part can be collected economically.
Why dry GCV?
Trash moisture varies widely with weather and storage; dry GCV is the stable property.
Problems?
Soil and potassium in trash raise ash, slagging and fouling: check the alkali index.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.