FireCADCalc

Bagasse Furnace Temperature (Hugot)

Theoretical furnace temperature for bagasse from moisture, sugar, excess air and air temperature with Hugot's mean gas specific heats (41.44–41.46).

Sugar mill and cogenerationBoiler

Inputs

Examples: Hugot example: w 0.48, m 1.5, air 30 °Cw 0.50, m 1.75w 0.48, m 1.5, air heated to 250 °C

Air leaving the air heater. Leave at 0 when the air enters at ambient temperature.
Hugot: 0.98–0.99 for step grates, horseshoe and spreader furnaces; 0.94–0.95 Ward.

Results

Hugot's table (αβ₀ = 0.96, air at 30 °C): about 1 100 °C at 45 % moisture and m = 1.5, 1 040 °C at 50 %.

Net calorific value 4250 − 4850w − 1200s7,540.4kJ/kg
Heat brought by the air above 0 °C (for information; not added to the balance)151.93kJ/kg
Furnace temperature with air at ambient954.06°C
Rise in furnace temperature per degree of air heating (Hugot 41.79)0.60689
Furnace temperature954.06°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example: w 0.48, m 1.5, air 30 °C. The inputs, in the units selected above:

InputValue
Bagasse moisture48.000 %
Sugar in bagasse2.0000 %
Air factor1.5000 -
Ambient temperature (bagasse and air before any heater)30.000 °C
Heated combustion air temperature (0 = air not heated)-273.15 °C
Combustion efficiency (unburnt)98.000 %
Furnace radiation factor99.000 %

Applying the formula below gives:

ResultValue
Net calorific value 4250 − 4850w − 1200s7,946.5 kJ/kg
Heat brought by the air above 0 °C (for information; not added to the balance)135.44 kJ/kg
Furnace temperature with air at ambient1,075.0 °C
Rise in furnace temperature per degree of air heating (Hugot 41.79)0.59489
Furnace temperature1,075.0 °C

Open this example in the calculator and change any input.

Formula

\((T_0 - t_0)\sum_i P_i(a_i + b_iT_0) = \alpha\beta_0 N, \quad N = 4250 - 4850w - 1200s\ [\mathrm{kcal/kg}]\)

\(\theta = \frac{T - T_0}{t - t_0} = \frac{1}{1.375 + \dfrac{1}{4.19(1 - w)m}}, \quad T = T_0 + \theta\,(t - t_0)\)

Variables

Symbol Meaning SI unit
\(w\) Bagasse moisture -
\(s\) Sugar in bagasse -
\(m\) Air factor -
\(t_0\) Ambient temperature of the bagasse and air before any heater K
\(t\) Heated combustion air temperature (0: air not heated, T = T₀) K
\(T_0\) Furnace temperature with air at ambient K
\(\theta\) Rise in furnace temperature per degree of air heating -
\(P_i\) Mass of product gas i per kg bagasse (Hugot's average composition) kg/kg
\(a_i\), \(b_i\) Mean specific heat coefficients of gas i, c = a + bT kcal/(kg·°C), kcal/(kg·°C²)
\(\alpha\) Combustion efficiency (unburnt) -
\(\beta_0\) Furnace radiation factor -
\(N\) Net calorific value 4250 − 4850w − 1200s J/kg
\(q_a\) Heat brought by the air above 0 °C (for information; not added to the balance) J/kg
\(T\) Furnace temperature K

Method and standards

Hugot's heat balance of the furnace gases (Handbook of Cane Sugar Engineering, 3rd ed., eqns 41.44–41.46) gives the temperature T₀ with air at ambient. For heated air, Hugot eqn 41.79 (p. 978) adds θ(t − t₀): only the air is heated, while the bagasse and its moisture enter cold, so the furnace gains less than the air heating, θ being about 0.6 for 46–48 % moisture and an air factor of 1.4–1.5 (Hugot p. 979).

Where it is used

  • Furnace design for bagasse boilers.
  • Judging moisture and excess air.

Common mistakes

  • Using GCV instead of NCV.
  • Too high an air factor in the estimate.

Assumptions and limits

  • Hugot's average composition and mean specific heats (0.24 for air, 0.33 for the gases in eqn 41.79).
  • t₀ is the ambient temperature; enter heated air separately, not as t₀.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 41
  • furnace temperature
  • eqns 41.44–41.46 and Tables 41.14–41.17
  • pp. 924–931

Questions and answers

Why does moisture matter so much?

Water in the bagasse absorbs heat to evaporate and then dilutes the gases; each point of moisture costs several degrees.

What are the mean specific heats?

Hugot's averages from 0 °C to T for N₂, O₂, H₂O and CO₂, linear in T.

Is this the real flame temperature?

It is the theoretical temperature before radiation to the walls; measured gas temperatures are lower.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.