Worked example
Example: Hugot example: w 0.48, m 1.5, air 30 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bagasse moisture | 48.000 % |
| Sugar in bagasse | 2.0000 % |
| Air factor | 1.5000 - |
| Ambient temperature (bagasse and air before any heater) | 30.000 °C |
| Heated combustion air temperature (0 = air not heated) | -273.15 °C |
| Combustion efficiency (unburnt) | 98.000 % |
| Furnace radiation factor | 99.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Net calorific value 4250 − 4850w − 1200s | 7,946.5 kJ/kg |
| Heat brought by the air above 0 °C (for information; not added to the balance) | 135.44 kJ/kg |
| Furnace temperature with air at ambient | 1,075.0 °C |
| Rise in furnace temperature per degree of air heating (Hugot 41.79) | 0.59489 |
| Furnace temperature | 1,075.0 °C |
Open this example in the calculator and change any input.
Formula
\((T_0 - t_0)\sum_i P_i(a_i + b_iT_0) = \alpha\beta_0 N, \quad N = 4250 - 4850w - 1200s\ [\mathrm{kcal/kg}]\)
\(\theta = \frac{T - T_0}{t - t_0} = \frac{1}{1.375 + \dfrac{1}{4.19(1 - w)m}}, \quad T = T_0 + \theta\,(t - t_0)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(w\) | Bagasse moisture | - |
| \(s\) | Sugar in bagasse | - |
| \(m\) | Air factor | - |
| \(t_0\) | Ambient temperature of the bagasse and air before any heater | K |
| \(t\) | Heated combustion air temperature (0: air not heated, T = T₀) | K |
| \(T_0\) | Furnace temperature with air at ambient | K |
| \(\theta\) | Rise in furnace temperature per degree of air heating | - |
| \(P_i\) | Mass of product gas i per kg bagasse (Hugot's average composition) | kg/kg |
| \(a_i\), \(b_i\) | Mean specific heat coefficients of gas i, c = a + bT | kcal/(kg·°C), kcal/(kg·°C²) |
| \(\alpha\) | Combustion efficiency (unburnt) | - |
| \(\beta_0\) | Furnace radiation factor | - |
| \(N\) | Net calorific value 4250 − 4850w − 1200s | J/kg |
| \(q_a\) | Heat brought by the air above 0 °C (for information; not added to the balance) | J/kg |
| \(T\) | Furnace temperature | K |
Method and standards
Hugot's heat balance of the furnace gases (Handbook of Cane Sugar Engineering, 3rd ed., eqns 41.44–41.46) gives the temperature T₀ with air at ambient. For heated air, Hugot eqn 41.79 (p. 978) adds θ(t − t₀): only the air is heated, while the bagasse and its moisture enter cold, so the furnace gains less than the air heating, θ being about 0.6 for 46–48 % moisture and an air factor of 1.4–1.5 (Hugot p. 979).
Where it is used
- Furnace design for bagasse boilers.
- Judging moisture and excess air.
Common mistakes
- Using GCV instead of NCV.
- Too high an air factor in the estimate.
Assumptions and limits
- Hugot's average composition and mean specific heats (0.24 for air, 0.33 for the gases in eqn 41.79).
- t₀ is the ambient temperature; enter heated air separately, not as t₀.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 41
- furnace temperature
- eqns 41.44–41.46 and Tables 41.14–41.17
- pp. 924–931
Questions and answers
Why does moisture matter so much?
Water in the bagasse absorbs heat to evaporate and then dilutes the gases; each point of moisture costs several degrees.
What are the mean specific heats?
Hugot's averages from 0 °C to T for N₂, O₂, H₂O and CO₂, linear in T.
Is this the real flame temperature?
It is the theoretical temperature before radiation to the walls; measured gas temperatures are lower.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.