Bagasse Dryer Using Flue Gas: Water Removed and Gas Exit

Water removed from bagasse in a flue-gas dryer, the heat it takes (IF97), the gas exit temperature and the bagasse net calorific value before and after drying.

Sugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 40 t/h, 50 to 42 %Hotter gas

Results

Water leaves as vapour at the gas exit temperature; dryer heat losses are neglected. Keep the gas exit above its dew point.

Water evaporated6.0000t/h
Heat taken from the gas4,403.3kW
Flue gas out145.64°C
Bagasse NCV before drying6,855.5kJ/kg
Bagasse NCV after drying9,182.8kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 t/h, 50 to 42 %. The inputs, in the units selected above:

InputValue
Wet bagasse40.000 t/h
Moisture in50.000 %
Moisture out42.000 %
Ash % bagasse (wet)2.5000 %
Brix % bagasse (wet)2.0000 %
Flue gas through the dryer160.00 t/h
Flue gas specific heat1.1000 kJ/(kg·K)
Flue gas in200.00 °C
Bagasse temperature in35.000 °C

Applying the formula below gives:

ResultValue
Water evaporated5.5172 t/h
Heat taken from the gas3,936.7 kW
Flue gas out119.48 °C
Bagasse NCV before drying7,375.0 kJ/kg
Bagasse NCV after drying8,947.6 kJ/kg

Open this example in the calculator and change any input.

Formula

\(\dot m_v = \dot m_b - \frac{\dot m_b (1 - W_1)}{1 - W_2}, \quad \dot Q = \dot m_v [h_v(T_{g,out}) - h_l(T_b)], \quad T_{g,out} = T_{g,in} - \frac{\dot Q}{\dot m_g c_{p,g}}\)

Variables

Symbol Meaning SI unit
\(\dot m_b\) Wet bagasse kg/s
\(W_1\) Moisture in -
\(W_2\) Moisture out -
\(A\) Ash % bagasse (wet) -
\(B_x\) Brix % bagasse (wet) -
\(\dot m_g\) Flue gas through the dryer kg/s
\(c_{p,g}\) Flue gas specific heat J/(kg·K)
\(T_{g,in}\) Flue gas in K
\(T_b\) Bagasse temperature in K
\(\dot m_v\) Water evaporated kg/s
\(\dot Q\) Heat taken from the gas W
\(T_{g,out}\) Flue gas out K
\(NCV_1\) Bagasse NCV before drying J/kg
\(NCV_2\) Bagasse NCV after drying J/kg

Method and standards

Mass balance of the water removed and an energy balance on the gas: the heat taken is the water evaporated from liquid at the bagasse temperature to vapour at the gas exit temperature (IAPWS-IF97 at 1 atm), solved by a short fixed-point iteration. Bagasse NCV by the sugar-industry equation, with ash and brix concentrating as water leaves.

Where it is used

  • Bagasse dryer studies.
  • Retrofits to raise steam per tonne of bagasse.

Common mistakes

  • Wet and dry basis mixed.
  • Exit gas below dew point.

Assumptions and limits

  • Adiabatic dryer.
  • The sensible heat to warm the dry bagasse and the water left in it is not included, so the heat taken and the gas temperature drop are slightly understated.
  • The gas dew point is not calculated; the page stops only if the gas would leave below about 60 °C. Check the exit against the dew point of your flue gas.

References

  • Mass balance; energy balance with IAPWS-IF97 enthalpies; bagasse NCV by the sugar-industry equation

Questions and answers

Why dry bagasse with flue gas?

Stack heat below the air heater is otherwise lost; drier bagasse burns hotter and raises steam per tonne.

Where does the dryer sit?

After the air heater or economiser, before the dust collector.

Fire risk?

Dry fines and hot gas: dryers need spark detection and quench.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.