Bagasse Boiler Surface, Furnace and Grate (Hugot)

Heating surface from the standard evaporation rate (Hugot 41.55–41.60), furnace volume (41.53) and grate area (41.54) of a bagasse boiler.

Sugar mill and cogenerationIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 50 t/h, 3-circuit boilerSpreader 100 t/h

Hugot Table 41.24: 2-circuit step grate 22; 3-circuit horseshoe or Ward 32; bent-tube spreader 36; up to 40 kg/(m²·h).
On the NCV basis, as the volume uses the NCV above. Hugot: 200 000 kcal/(m³·h) on NCV; his spreader figures up to about 260 000 are on GCV and must be converted to NCV first.
Hugot: step grates 500–1000; horseshoe 1300–1800; spreaders designed near 800 kg/(m²·h).

Results

Hugot's French standard evaporation is referred to 639 kcal per kg of steam. He reports 30–75 m² of surface per m² of grate (about 50 for spreaders).

Heat per kg of steam2,857.0kJ/kg
Actual evaporation rate33.711kg/(m²·h)
Heating surface2,966.4m²
Bagasse fired43.478t/h
Furnace volume375.49m³
Grate area43.478m²
Heating surface per grate area68.226

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 t/h, 3-circuit boiler. The inputs, in the units selected above:

InputValue
Steam50.000 t/h
Steam pressure (absolute)28.439 bar
Steam temperature380.00 °C
Feed water temperature90.000 °C
Standard (French) evaporation rate32.000 kg/(m²·h)
Steam per kg bagasse2.2000 -
Net calorific value of the bagasse1,900.0 kcal/kg
Furnace heat release per m³232.60 kW/m³
Grate loading800.00 kg/(m²·h)

Applying the formula below gives:

ResultValue
Heat per kg of steam2,809.6 kJ/kg
Actual evaporation rate30.471 kg/(m²·h)
Heating surface1,640.9 m²
Bagasse fired22.727 t/h
Furnace volume215.91 m³
Grate area28.409 m²
Heating surface per grate area57.760

Open this example in the calculator and change any input.

Formula

\(\tau = \tau_0\frac{639}{h}, \quad S = \frac{Q}{\tau}, \quad B = \frac{Q}{r}, \quad V = \frac{BN}{q_v}, \quad s_g = \frac{B}{\beta}\)

Variables

Symbol Meaning SI unit
\(Q\) Steam kg/s
\(p_s\) Steam pressure (absolute) Pa
\(T_s\) Steam temperature K
\(t_f\) Feed water temperature K
\(\tau_0\) Standard (French) evaporation rate kg/(m²·s)
\(r\) Steam per kg bagasse -
\(N\) Net calorific value of the bagasse J/kg
\(q_v\) Furnace heat release per m³ W/m³
\(\beta\) Grate loading kg/(m²·s)
\(h\) Heat per kg of steam J/kg
\(\tau\) Actual evaporation rate kg/(m²·s)
\(S\) Heating surface m²
\(B\) Bagasse fired kg/s
\(V\) Furnace volume m³
\(s_g\) Grate area m²
\(S/s_g\) Heating surface per grate area -

Method and standards

Hugot's sizing rules.

Where it is used

  • First sizing of bagasse boilers.
  • Checking boiler offers.

Common mistakes

  • Mixing French and English standard evaporation.
  • Using GCV in the furnace volume.

Assumptions and limits

  • Hugot's practice figures.
  • The furnace heat release must be on the NCV basis, like the NCV entered; convert GCV-based figures first.
  • Steam superheated (or dry) and feed water liquid and colder; otherwise the page stops.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 41
  • eqns 41.53–41.60 and Tables 41.23–41.24
  • pp. 944–958
  • Steam and feed enthalpies from IAPWS-IF97

Questions and answers

What is standard evaporation?

The evaporation per m² converted to a reference heat of 639 kcal per kg (French) or 539 (English), so boilers at different conditions compare.

Why is the furnace volume large for bagasse?

Wet bagasse burns partly in suspension and needs time and space.

Grate loading?

Hugot: step grates 500–1000 kg/(m²·h), horseshoe furnaces 1300–1800, spreaders designed near 800.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.