FireCADCalc

Condensate Polishing Unit: Permeate and Reject

Permeate and reject flows and COD of a condensate polishing (RO) unit from the condensate flow, the recovery, the feed COD and the membrane rejection.

Distillery and ethanolWater treatment plant

Inputs

Examples: 650 m3/d at 85 %Two-pass recovery

Results

The reject usually returns to the evaporator; check its COD against what the evaporator can take.

Permeate360.00m³/d
Reject40.000m³/d
Permeate COD75.000mg/L
Reject COD24,325mg/L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 650 m3/d at 85 %. The inputs, in the units selected above:

InputValue
Process condensate650.00 m³/d
Recovery (permeate / feed)85.000 %
Feed COD1,500.0 mg/L
COD rejection by the membranes95.000 %

Applying the formula below gives:

ResultValue
Permeate552.50 m³/d
Reject97.500 m³/d
Permeate COD75.000 mg/L
Reject COD9,575.0 mg/L

Open this example in the calculator and change any input.

Formula

\(\dot V_p = \dot V R, \quad c_p = c_f (1 - \rho_r), \quad c_r = \frac{\dot V c_f - \dot V_p c_p}{\dot V - \dot V_p}\)

Variables

Symbol Meaning SI unit
\(\dot V\) Process condensate m³/s
\(R\) Recovery (permeate / feed) -
\(c_f\) Feed COD kg/m³
\(\rho_r\) COD rejection by the membranes -
\(\dot V_p\) Permeate m³/s
\(\dot V_r\) Reject m³/s
\(c_p\) Permeate COD kg/m³
\(c_r\) Reject COD kg/m³

Method and standards

Mass balance.

Where it is used

  • CPU sizing.
  • ZLD balance.

Common mistakes

  • Rejection applied to the reject.

Assumptions and limits

  • Single stage.
  • The rejection is applied to the feed COD. In a real RO stage the permeate follows the mean feed-side concentration, which rises with recovery, so at high recovery the permeate COD here is understated and the reject COD overstated.

References

  • Flow and solute balance across a membrane stage with a rejection

Questions and answers

Why polish condensate?

Evaporator condensate carries volatile organics; polished, it replaces fresh water.

Recovery limit?

Fouling and the reject's strength; 80–90 % is common.

Rejection?

The share of COD the membrane holds back; volatile acids pass more easily.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators