Worked example
Example: 3000 m2 godown. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Floor area | 3,000.0 m² |
| Share of floor usable for stacks | 70.000 % |
| Stack height | 6.0000 m |
| Stacking density of bagged sugar | 800.00 kg/m³ |
| Bag mass | 50.000 kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Capacity | 10,080 t |
| Bags | 201,600 |
Open this example in the calculator and change any input.
Formula
\(M = A\,u\,H\,\rho_s, \quad N_b = \left\lfloor\frac{M}{m_b}\right\rfloor\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Floor area | m² |
| \(u\) | Share of floor usable for stacks | - |
| \(H\) | Stack height | m |
| \(\rho_s\) | Stacking density of bagged sugar | kg/m³ |
| \(m_b\) | Bag mass | kg |
| \(M\) | Capacity | kg |
| \(N_b\) | Bags | - |
Method and standards
Definitions.
Where it is used
- Warehouse planning.
- Season stock planning.
Common mistakes
- Full floor area used.
Assumptions and limits
- Uniform stacks.
- The default usable share and stacking density are typical figures, not from a cited source.
- The floor load ρ_s H g is shown in a note; check it against the floor rating, especially for high stacks.
References
- Volume × stacking density; usable share and density by practice
Questions and answers
Why only part of the floor?
Gangways, fire lanes and clearances from walls take space.
Stacking density?
Bagged sugar in stacks is roughly 0.75–0.85 t/m³; measure for your bags.
Days of storage?
Divide capacity by sugar made per day.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.