FireCADCalc

Sugar Safety Factor, Dilution Indicator and Titre

Keeping quality of raw sugar by safety factor and dilution indicator (Hugot eqns 36.1–36.2), and its titre (37.6), net titre (37.7) and the EEC titre 2P − 100.

Sugar mill and cogeneration

Inputs

Examples: Raw sugar 98.5 polRisky raw sugar

Results

Hugot: safety factor below 0.25–0.3 keeps; dilution indicator above 50 (safety factor 0.33) is risky. He prefers the dilution indicator.

The dilution indicator is 60, above 50: this sugar is at risk of deterioration in storage.

Safety factor0.37500
Dilution indicator60.000
Titre pol − (2r + 4c)94.400%
Net titre pol − (r + 5c)94.500%
EEC titre 2P − 10095.200%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Raw sugar 98.5 pol. The inputs, in the units selected above:

InputValue
Polarisation98.500 %
Moisture0.40000 %
Reducing sugars0.40000 %
Ash (on the basis of the titre definition used)0.30000 %

Applying the formula below gives:

ResultValue
Safety factor0.26667
Dilution indicator36.364
Titre pol − (2r + 4c)96.500 %
Net titre pol − (r + 5c)96.600 %
EEC titre 2P − 10097.000 %

Open this example in the calculator and change any input.

Formula

\(f = \frac{H}{100 - Pol}, \quad D.I. = \frac{100H}{100 - (Pol + H)}, \quad T = Pol - (2r + 4c), \quad T_n = Pol - (r + 5c)\)

Variables

Symbol Meaning SI unit
\(Pol\) Polarisation -
\(H\) Moisture -
\(r\) Reducing sugars -
\(c\) Ash (on the basis of the titre definition used) -
\(f\) Safety factor -
\(D.I.\) Dilution indicator -
\(T\) Titre pol − (2r + 4c) -
\(T_n\) Net titre pol − (r + 5c) -
\(T_E\) EEC titre 2P − 100 -

Method and standards

Definitions as given by Hugot.

Where it is used

  • Storage decisions.
  • Raw sugar valuation.

Common mistakes

  • Mixing moisture on wet and dry basis.
  • Using conductivity ash factors inconsistently.

Assumptions and limits

  • Percentages on sugar.
  • Ash on the basis the titre definition calls for (sulphated or conductivity ash); the page does not convert between them.
  • The safety factor and dilution indicator are compared with Hugot's thresholds in a note.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 36
  • eqns 36.1–36.2
  • p. 817; ch. 37
  • eqns 37.6–37.7
  • pp. 834–835

Questions and answers

What does the safety factor measure?

Water relative to non-pol: the film of syrup on the crystals; too much water lets microbes work.

Why the dilution indicator?

It is the moisture as a share of the non-pol syrup film, a direct measure of its dilution.

What is titre?

The French basis for valuing raw sugar: pol less penalties for reducing sugars and ash.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.