Sugar Dryer: Water Removed and Air Flow

Water removed in a sugar dryer from the sugar flow and moisture in and out, and the dry-air flow from the humidity rise of the air.

Sugar mill and cogeneration

Inputs

Examples: 25 t/h, 1 % to 0.05 %Refined sugar

Used only to check that the exit humidity is below saturation at 1 atm.

Results

Water removed92.428kg/h
Dry air needed18,486kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 25 t/h, 1 % to 0.05 %. The inputs, in the units selected above:

InputValue
Wet sugar to dryer25.000 t/h
Moisture in (wet basis)1.0000 %
Moisture out (wet basis)0.050000 %
Air humidity in8.0000 g/kg
Air humidity out12.000 g/kg
Air temperature out (to check saturation)40.000 °C

Applying the formula below gives:

ResultValue
Water removed237.62 kg/h
Dry air needed59,405 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot m_w = \dot m (1 - w_1)\left(\frac{w_1}{1-w_1} - \frac{w_2}{1-w_2}\right), \quad \dot m_a = \frac{\dot m_w}{Y_2 - Y_1}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Wet sugar to dryer kg/s
\(w_1\) Moisture in (wet basis) -
\(w_2\) Moisture out (wet basis) -
\(Y_1\) Air humidity in kg/kg
\(Y_2\) Air humidity out kg/kg
\(T_e\) Air temperature out (to check saturation) K
\(\dot m_w\) Water removed kg/s
\(\dot m_a\) Dry air needed kg/s

Method and standards

Mass balance.

Where it is used

  • Dryer and cooler sizing.

Common mistakes

  • Wet and dry basis mixed.

Assumptions and limits

  • Steady state.
  • The exit humidity must be below saturation at the exit air temperature (checked at 1 atm).

References

  • Solids and moisture balance; air humidity balance (psychrometrics)

Questions and answers

Why so little water?

Sugar leaves the centrifugals with about 0.5–1.5 % moisture.

Why does it matter?

Moist sugar cakes and grows microbes in storage.

Air heated?

Heating raises the humidity it can take; then it needs a cooler stage.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators