FireCADCalc

Continuous Centrifugal: Sugar, Molasses and G

Sugar and molasses from a continuous centrifugal by the purity balance (Delden, Hugot p. 802), wash water per m³ and the gravity factor at the basket rim.

Sugar mill and cogeneration

Inputs

Examples: Delden example, molasses 35Molasses 30

Hugot: C 4–8, B 7–15, A 20–30 t/h per machine.
Litres per m³; Hugot: 15–25 for C massecuite (Mauritius 35).

Results

Delden's example (P_s 96, P_m 56, B_m 98): molasses at 35 purity gives 32.4 % crystal, at 30 purity 37.1 %. Crystals leave at about rim speed; 9–18 m/s impact breaks them.

Sugar and molasses are dry solids. Wash water is not in the dry-solids balance: it leaves as water with the molasses, and the crystal it dissolves shows in the measured molasses purity, so enter the purity measured with washing on.

Sucrose in the sugar % massecuite (Delden; crystal plus its molasses film)37.062%
Sugar dry solids per massecuite38.606%
Sugar (dry solids)3.0885t/h
Molasses (dry solids)4.7515t/h
Wash water133.33L/h
Gravity factor at the rim (top diameter)1,883.5
Rim speed100.79m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Delden example, molasses 35. The inputs, in the units selected above:

InputValue
Massecuite fed8.0000 t/h
Massecuite brix98.000 %
Massecuite purity56.000 %
Sugar purity96.000 %
Molasses purity35.000 %
Massecuite density1,500.0 kg/m³
Wash water per m³ massecuite20.000 -
Basket top diameter1.0000 m
Speed1,800.0 rpm

Applying the formula below gives:

ResultValue
Sucrose in the sugar % massecuite (Delden; crystal plus its molasses film)32.388 %
Sugar dry solids per massecuite33.738 %
Sugar (dry solids)2.6990 t/h
Molasses (dry solids)5.1410 t/h
Wash water106.67 L/h
Gravity factor at the rim (top diameter)1,811.6
Rim speed94.248 m/s

Open this example in the calculator and change any input.

Formula

\(\frac{S}{Q} = B_m\frac{P_m - P_e}{P_s - P_e}, \quad x = P_s\frac{S}{Q}, \quad \dot m_s = Q\frac{S}{Q}, \quad \dot m_M = Q\left(B_m - \frac{S}{Q}\right)\)

\(\dot V_w = \frac{Q}{\rho_m}\,\frac{w}{1000}, \quad \omega = 2\pi n, \quad G = \frac{\omega^2 D}{2g}, \quad v = \frac{\omega D}{2}\)

Variables

Symbol Meaning SI unit
\(Q\) Massecuite fed kg/s
\(B_m\) Massecuite brix -
\(P_m\) Massecuite purity -
\(P_s\) Sugar purity -
\(P_e\) Molasses purity -
\(\rho_m\) Massecuite density kg/m³
\(w\) Wash water per m³ massecuite (litres per m³) -
\(D\) Basket top diameter m
\(n\) Speed 1/s
\(x\) Sucrose in the sugar % massecuite (Delden; crystal plus its molasses film) -
\(S/Q\) Sugar dry solids per massecuite -
\(\dot m_s\) Sugar (dry solids) kg/s
\(\dot m_M\) Molasses (dry solids) kg/s
\(\dot V_w\) Wash water m³/s
\(G\) Gravity factor at the rim (top diameter) -
\(\omega\) Angular speed rad/s
\(g\) Standard gravity m/s²
\(v\) Rim speed m/s

Method and standards

Purity balance and centrifugal force.

Where it is used

  • Selecting continuous machines.
  • Low-grade station balances.

Common mistakes

  • Using refractometric brix with gravity purities.
  • Ignoring wash dilution of molasses.

Assumptions and limits

  • Steady feed; no crystals through the screen.
  • Sugar and molasses outputs are dry solids, not product masses; the wash water leaves with the molasses and is not in the dry-solids balance. Crystal dissolved by the wash is accounted for only through the measured molasses purity.
  • G and rim speed are at the top (largest) diameter of the conical basket; the mean G over the cone is lower.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 35
  • continuous centrifugals
  • eqns 35.46–35.51 and Delden's crystal content
  • pp. 794–806

Questions and answers

Why quote capacity in massecuite?

The machine is limited by the massecuite it can handle; sugar output depends on the crystal content.

Does washing hurt exhaustion?

Yes: continuous machines need some wash on C massecuite, raising molasses purity by up to a point.

Why large casings?

To slow crystals in air before they hit the wall and break.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.