FireCADCalc

Batch Centrifugal Power: Running, Acceleration, Recovery

Running power of a batch centrifugal from Hugot's friction couple (eqn 35.38), the energy to accelerate it and the energy regenerative braking recovers.

Sugar mill and cogenerationElectric motor

Inputs

Examples: 1 065 x 760 at 1 500 rpm1 220 x 760 at 1 200 rpm

From the maker; Hugot's Table 35.10 lists values for common sizes.

Results

Hugot's running couple C = D⁴Hn(1 + 4n) m·kgf, n in thousands of rpm. The acceleration power excludes friction during the run-up and the drive efficiency: size the motor above it.

Running friction couple114.92N·m
Running power14.441kW
Kinetic energy at top speed1.5353kWh
Mean power to accelerate73.693kW
Energy regenerative braking returns1.1515kWh

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 065 x 760 at 1 500 rpm. The inputs, in the units selected above:

InputValue
Basket diameter1.0650 m
Basket height0.76000 m
Top speed1,500.0 rpm
Moment of inertia of basket and charge400.00 kg·m²
Acceleration time60.000 s
Speed at which regenerative braking ends (share of top speed)60.000 %

Applying the formula below gives:

ResultValue
Running friction couple100.68 N·m
Running power15.814 kW
Kinetic energy at top speed1.3708 kWh
Mean power to accelerate82.247 kW
Energy regenerative braking returns0.87730 kWh

Open this example in the calculator and change any input.

Formula

\(C = D^4 H n_k(1 + 4n_k)\ \mathrm{m\,kgf}\ (n_k = n/1000), \quad P_r = C\omega, \quad E_k = \tfrac12 I\omega^2, \quad P_a = \frac{E_k}{t_a}, \quad E_r = E_k(1 - f^2)\)

Variables

Symbol Meaning SI unit
\(D\) Basket diameter m
\(H\) Basket height m
\(n\) Top speed 1/s
\(I\) Moment of inertia of basket and charge kg·m²
\(t_a\) Acceleration time s
\(f\) Speed at which regenerative braking ends (share of top speed) -
\(C\) Running friction couple N·m
\(P_r\) Running power W
\(E_k\) Kinetic energy at top speed J
\(P_a\) Mean power to accelerate W
\(E_r\) Energy regenerative braking returns J

Method and standards

Hugot's couple with rigid-body energy.

Where it is used

  • Sizing centrifugal motors.
  • Valuing regenerative drives.

Common mistakes

  • Using rpm instead of thousands of rpm in the couple.
  • Forgetting the charge in the inertia.

Assumptions and limits

  • Rigid basket; constant inertia during acceleration.
  • P_a is the kinetic energy over the acceleration time: it excludes the friction power during run-up and the drive efficiency, so a motor sized on it alone is too small. E_r assumes the drive returns all of the braking energy; drive losses reduce it.
  • For a 1 065 × 760 mm basket at 1 500 rpm the couple gives about 16 kW, as in Hugot's Table 35.11.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 35
  • power of centrifugals
  • eqns 35.33–35.40 and Table 35.11
  • pp. 775–782
  • Kinetic energy ½Iω²

Questions and answers

Where does most energy go?

Into accelerating the basket and charge each cycle; running at speed takes much less.

How much does regenerative braking save?

Braking from top speed to 60 % returns 1 − 0.6² = 64 % of the kinetic energy, less drive losses.

Why does the couple rise with speed?

Air drag and bearing friction grow with speed, which Hugot's (1 + 4n) term captures.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.