Worked example
Example: DN150 sch 40 (168.3 x 7.11 mm) at 10 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Internal pressure (above the outside pressure) | 10.000 bar |
| Outside diameter | 168.30 mm |
| Wall thickness | 7.1100 mm |
| Stress to check against (0 = none) | 0 MPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hoop stress, Barlow (on outside diameter) | 11.835 MPa |
| Hoop stress on mean diameter | 11.335 MPa |
| Longitudinal stress (closed ends) | 5.6677 MPa |
Open this example in the calculator and change any input.
Formula
\(\sigma_h = \frac{p D_o}{2 t}\)
\(\sigma_{h,m} = \frac{p (D_o - t)}{2 t}, \quad \sigma_l = \frac{p (D_o - t)}{4 t}\)
\(p_S = \frac{2 S t}{D_o}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | internal pressure above the outside | Pa |
| \(D_o\) | outside diameter | m |
| \(t\) | wall thickness | m |
| \(S\) | stress to check against | Pa |
| \(\sigma_h\) | hoop stress, Barlow | Pa |
| \(\sigma_{h,m}\) | hoop stress on mean diameter | Pa |
| \(\sigma_l\) | longitudinal stress | Pa |
| \(p_S\) | pressure giving the stress S | Pa |
Method and standards
Equilibrium of half a thin ring gives the hoop stress; Barlow's form uses the outside diameter and is slightly conservative. The longitudinal stress in a closed-ended cylinder is half the hoop stress.
Where it is used
- Quick checks of pipe and vessel stresses.
- Estimating test pressures for a known material stress.
- Teaching and checking calculations.
Common mistakes
- Using it as a code design thickness.
- Using absolute pressure instead of the pressure difference.
- Applying thin-wall formulas to thick walls.
Assumptions and limits
- Thin wall (D/t above about 20), uniform internal pressure.
- No corrosion allowance, tolerance or weld efficiency.
References
- Barlow's formula
- Thin-wall cylinder theory
Questions and answers
What hoop stress does a DN150 sch 40 pipe see at 10 bar?
About 11.8 MPa by Barlow (168.3 mm OD, 7.11 mm wall); the longitudinal stress is half that.
Is this a code wall thickness?
No. Design codes add joint efficiency, corrosion allowance, mill tolerance and temperature factors; use them for design.
When is the thin-wall formula not good enough?
When D/t is below about 20: use Lamé's thick-cylinder equations, which give a higher stress at the bore.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.