FireCADCalc

Rankine–Gordon Column Crippling Load

Crippling and safe load of a column by the Rankine–Gordon formula from area, second moment, effective length, crushing stress and Rankine's constant, against Euler.

Inputs

Examples: Illustrative mild steel strutCast iron columnTimber post

Accepted: 1 to 10,000,000 mm²
Accepted: 1E-4 to 1E+9 cm⁴
Accepted: 0.01 to 100 m
Accepted: 1 to 2,000 MPa
Accepted: 1 to 500 GPa
Accepted: 1 to 10

Results

Rankine and Gordon combined crushing and buckling: 1/P = 1/P_c + 1/P_E, written P = σ_cA/[1 + a(L_e/k)²] with Rankine's constant a ≈ σ_c/(π²E). It approaches the crushing load for short columns and the Euler load for long ones, so a single formula covers the whole range. Use the least radius of gyration and the effective length for the end conditions (L for pinned ends, L/2 fixed–fixed, 2L for a cantilever).

Least radius of gyration44.721mm
Slenderness ratio89.443
Rankine crippling load550.00kN
Safe load110.00kN
Euler load740.22kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative mild steel strut. The inputs, in the units selected above:

InputValue
Cross-section area2,000.0 mm²
Least second moment of area200.00 cm⁴
Effective length3.0000 m
Crushing stress320.00 MPa
Rankine's constantMild steel, 1/7500
Young's modulus (for Euler)210.00 GPa
Factor of safety3.0000 -

Applying the formula below gives:

ResultValue
Least radius of gyration31.623 mm
Slenderness ratio94.868
Rankine crippling load290.91 kN
Safe load96.970 kN
Euler load460.58 kN

Open this example in the calculator and change any input.

Formula

\(P_R = \frac{\sigma_cA}{1 + a\left(\frac{L_e}{k}\right)^2}, \quad k = \sqrt{\frac IA}, \quad P_E = \frac{\pi^2EI}{L_e^2}\)

Variables

Symbol Meaning SI unit
\(A\) Cross-section area m²
\(I\) Least second moment of area m⁴
\(L_e\) Effective length m
\(\sigma_c\) Crushing stress Pa
\(a\) Rankine's constant -
\(E\) Young's modulus (for Euler) Pa
\(FS\) Factor of safety -
\(k\) Least radius of gyration m
\(L_e/k\) Slenderness ratio -
\(P_R\) Rankine crippling load N
\(P_s\) Safe load N
\(P_E\) Euler load N

Method and standards

Rankine–Gordon.

Where it is used

  • Strut and column checks.
  • Strength of materials examinations.

Common mistakes

  • Using the greater radius of gyration.
  • Using actual instead of effective length.

Assumptions and limits

  • Axial load; straight column.

References

  • Rankine–Gordon column formula

Questions and answers

What load cripples a mild steel strut of 2,000 mm², I = 200 cm⁴, 3 m effective length?

About 291 kN by Rankine (Euler gives 461 kN); safe load 97 kN at a factor of 3.

Why does Rankine give less than Euler here?

At slenderness 95 crushing still matters; Euler ignores it.

What do the defaults represent?

An illustrative mild steel strut, area 2,000 mm², least I 200 cm⁴, 3 m effective length, crushing stress 320 MPa, a = 1/7500, E 210 GPa, factor of safety 3.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.