Worked example
Example: 40 mm round steel bar, 1.2 m (Johnson). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Effective length (K L) | 1.2000 m |
| Cross-sectional area | 1,256.6 mm² |
| Least radius of gyration | 10.000 mm |
| Young's modulus | 207.00 GPa |
| Yield strength | 250.00 MPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Slenderness ratio | 120.00 |
| Transition slenderness √(2π² E/S_y) | 127.84 |
| Critical load | 175.76 kN |
| Critical stress | 139.87 MPa |
Open this example in the calculator and change any input.
Formula
\(\left(\frac{L_e}{k}\right)_1 = \sqrt{\frac{2\pi^2 E}{S_y}}, \quad \frac{P_{cr}}{A} = S_y - \left(\frac{S_y L_e}{2\pi k}\right)^2 \frac{1}{E}\ \text{(Johnson)}, \quad \frac{P_{cr}}{A} = \frac{\pi^2 E}{(L_e/k)^2}\ \text{(Euler)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_e\) | Effective length (K L) | m |
| \(A\) | Cross-sectional area | m² |
| \(k\) | Least radius of gyration | m |
| \(E\) | Young's modulus | Pa |
| \(S_y\) | Yield strength | Pa |
| \(L_e/k\) | Slenderness ratio | - |
| \((L_e/k)_1\) | Transition slenderness √(2π² E/S_y) | - |
| \(P_{cr}\) | Critical load | N |
| \(P_{cr}/A\) | Critical stress | Pa |
Method and standards
Parabola tangent to Euler's curve at half the yield strength.
Where it is used
- Struts, links and jack screws.
- Machine design examinations.
Common mistakes
- Using the larger radius of gyration.
- No safety factor on P_cr.
Assumptions and limits
- Straight, centrally loaded column.
- P_cr is the failure (critical) load with no factor of safety: divide by your design factor. The Euler-only calculator gives the same long-column result.
References
- Budynas and Nisbett
- Shigley's Mechanical Engineering Design
- 10th ed. (McGraw-Hill, 2015)
- ch. 4 (Euler and J.B. Johnson column formulas)
Questions and answers
A 40 mm round steel bar, 1.2 m effective length?
k = 10 mm, slenderness 120, transition 128: Johnson governs.
Why not Euler for short columns?
Euler predicts stresses above yield; Johnson's parabola joins yield at zero length.
What is effective length?
K L: 1 pinned-pinned, 0.5 fixed-fixed, 2 free-fixed (theoretical).
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.