FireCADCalc

Column Buckling: Johnson and Euler Formulas

Critical load of a pin-ended or other column by the Johnson parabola for intermediate columns and Euler for long columns, with the slenderness ratio and transition.

Inputs

Examples: 40 mm round steel bar, 1.2 m (Johnson)Same bar, 2.5 m (Euler)Aluminium tube: 0.8 m, 600 mm², k 15 mm, 70 GPa, 240 MPa

Results

Intermediate column: Johnson's parabola governs.

Slenderness ratio120.00
Transition slenderness √(2π² E/S_y)127.84
Critical load175.76kN
Critical stress139.87MPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 mm round steel bar, 1.2 m (Johnson). The inputs, in the units selected above:

InputValue
Effective length (K L)1.2000 m
Cross-sectional area1,256.6 mm²
Least radius of gyration10.000 mm
Young's modulus207.00 GPa
Yield strength250.00 MPa

Applying the formula below gives:

ResultValue
Slenderness ratio120.00
Transition slenderness √(2π² E/S_y)127.84
Critical load175.76 kN
Critical stress139.87 MPa

Open this example in the calculator and change any input.

Formula

\(\left(\frac{L_e}{k}\right)_1 = \sqrt{\frac{2\pi^2 E}{S_y}}, \quad \frac{P_{cr}}{A} = S_y - \left(\frac{S_y L_e}{2\pi k}\right)^2 \frac{1}{E}\ \text{(Johnson)}, \quad \frac{P_{cr}}{A} = \frac{\pi^2 E}{(L_e/k)^2}\ \text{(Euler)}\)

Variables

Symbol Meaning SI unit
\(L_e\) Effective length (K L) m
\(A\) Cross-sectional area m²
\(k\) Least radius of gyration m
\(E\) Young's modulus Pa
\(S_y\) Yield strength Pa
\(L_e/k\) Slenderness ratio -
\((L_e/k)_1\) Transition slenderness √(2π² E/S_y) -
\(P_{cr}\) Critical load N
\(P_{cr}/A\) Critical stress Pa

Method and standards

Parabola tangent to Euler's curve at half the yield strength.

Where it is used

  • Struts, links and jack screws.
  • Machine design examinations.

Common mistakes

  • Using the larger radius of gyration.
  • No safety factor on P_cr.

Assumptions and limits

  • Straight, centrally loaded column.
  • P_cr is the failure (critical) load with no factor of safety: divide by your design factor. The Euler-only calculator gives the same long-column result.

References

  • Budynas and Nisbett
  • Shigley's Mechanical Engineering Design
  • 10th ed. (McGraw-Hill, 2015)
  • ch. 4 (Euler and J.B. Johnson column formulas)

Questions and answers

A 40 mm round steel bar, 1.2 m effective length?

k = 10 mm, slenderness 120, transition 128: Johnson governs.

Why not Euler for short columns?

Euler predicts stresses above yield; Johnson's parabola joins yield at zero length.

What is effective length?

K L: 1 pinned-pinned, 0.5 fixed-fixed, 2 free-fixed (theoretical).

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.