Worked example
Example: Transfer pump: tank 1 atm, 2 m flooded, to tank at 15 m, 3.5 m losses. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pressure in the suction vessel (absolute) | 1.0132 bar |
| Pressure in the discharge vessel (absolute) | 1.0132 bar |
| Suction liquid level above the pump centreline | 2.0000 m |
| Discharge point (or liquid level) above the pump centreline | 15.000 m |
| Friction loss in the suction line | 0.50000 m |
| Friction loss in the discharge line, valves and equipment | 3.0000 m |
| Liquid density | 998.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pump total head | 16.500 m |
| Pressure rise across the pump | 161.49 kPa |
| Pressure at the pump suction (absolute) | 1.1601 bar |
| Pressure at the pump discharge (absolute) | 2.7749 bar |
| Pressure head | 0 m |
| Static head | 13.000 m |
| Friction head | 3.5000 m |
Open this example in the calculator and change any input.
Formula
\(H = \frac{p_d - p_s}{\rho g} + (z_d - z_s) + h_{fs} + h_{fd} = H_p + H_z + H_f \qquad \Delta p = \rho g H\)
\(p_1 = p_s + \rho g\,(z_s - h_{fs}) \qquad p_2 = p_1 + \rho g H\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_s\) | pressure in the suction vessel, absolute | Pa |
| \(p_d\) | pressure in the discharge vessel, absolute | Pa |
| \(z_s\) | suction liquid level above the pump centreline | m |
| \(z_d\) | discharge point above the pump centreline | m |
| \(h_{fs}\) | suction line friction loss | m |
| \(h_{fd}\) | discharge line, valve and equipment losses | m |
| \(\rho\) | liquid density | kg/m³ |
| \(H\) | pump total head | m |
| \(\Delta p\) | pressure rise across the pump | Pa |
| \(p_1\) | pressure at the pump suction | Pa |
| \(p_2\) | pressure at the pump discharge | Pa |
| \(H_p\) | pressure head | m |
| \(H_z\) | static head | m |
| \(H_f\) | friction head | m |
| \(g\) | standard gravity, 9.806 65 | m/s² |
Method and standards
Energy balance between the liquid surfaces of the suction and discharge vessels, with total head as defined in ANSI/HI 1.6.
Where it is used
- Specifying pumps for feed, transfer and cooling water.
- Checking an existing pump against a new system.
- Building system curves.
Common mistakes
- Forgetting the pressure difference between suction and discharge vessels.
- Using gauge and absolute pressures together.
- Adding margin twice, on head and on flow.
Assumptions and limits
- Liquid surfaces at rest; for a free discharge to atmosphere add the exit velocity head to the losses.
- Losses at the design flow (use the pipe pressure drop calculator); the head at other flows follows the system curve.
- Constant density.
- Vapour pressure is not checked here: a positive suction pressure does not mean the pump is free of cavitation. Check the margin with the NPSH available calculator.
References
- ANSI/HI 1.6 (total head definition)
Questions and answers
How do I calculate pump total head?
Add the pressure head between the vessels, the static height and all friction losses. A transfer pump from an open tank 2 m above it to an open tank 15 m up, with 3.5 m of losses, needs 13 + 3.5 = 16.5 m.
Why does a condensate pump need so much head?
It lifts water from a hot well under vacuum into a pressurised deaerator. From 0.12 bar(a) to 6 bar(a) the pressure head alone is 61 m.
Are velocity heads included?
Between two vessels the liquid surfaces are at rest, so the velocity heads cancel. Entry and exit losses belong in the friction losses.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.