FireCADCalc

Pump Total Head (Vessel to Vessel)

Total head a pump must develop between a suction and a discharge vessel: pressure, static and friction heads, with the pump suction and discharge pressures.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserHydraulic Institute (pumps)Pump

Inputs

Examples: Transfer pump: tank 1 atm, 2 m flooded, to tank at 15 m, 3.5 m lossesMake-up pump to deaerator at 1.2 bar(a), 20 m upCondensate pump: hot well 0.12 bar(a) to deaerator 6 bar(a), 25 m up

Atmospheric for an open tank. Absolute; choose a gauge unit to enter gauge readings.
Negative for a suction lift.

Results

Pump total head92.172m
Pressure rise across the pump890.34kPa
Pressure at the pump suction (absolute)0.28421bar
Pressure at the pump discharge (absolute)9.1877bar
Pressure head60.872m
Static head23.000m
Friction head8.3000m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Transfer pump: tank 1 atm, 2 m flooded, to tank at 15 m, 3.5 m losses. The inputs, in the units selected above:

InputValue
Pressure in the suction vessel (absolute)1.0132 bar
Pressure in the discharge vessel (absolute)1.0132 bar
Suction liquid level above the pump centreline2.0000 m
Discharge point (or liquid level) above the pump centreline15.000 m
Friction loss in the suction line0.50000 m
Friction loss in the discharge line, valves and equipment3.0000 m
Liquid density998.00 kg/m³

Applying the formula below gives:

ResultValue
Pump total head16.500 m
Pressure rise across the pump161.49 kPa
Pressure at the pump suction (absolute)1.1601 bar
Pressure at the pump discharge (absolute)2.7749 bar
Pressure head0 m
Static head13.000 m
Friction head3.5000 m

Open this example in the calculator and change any input.

Formula

\(H = \frac{p_d - p_s}{\rho g} + (z_d - z_s) + h_{fs} + h_{fd} = H_p + H_z + H_f \qquad \Delta p = \rho g H\)

\(p_1 = p_s + \rho g\,(z_s - h_{fs}) \qquad p_2 = p_1 + \rho g H\)

Variables

Symbol Meaning SI unit
\(p_s\) pressure in the suction vessel, absolute Pa
\(p_d\) pressure in the discharge vessel, absolute Pa
\(z_s\) suction liquid level above the pump centreline m
\(z_d\) discharge point above the pump centreline m
\(h_{fs}\) suction line friction loss m
\(h_{fd}\) discharge line, valve and equipment losses m
\(\rho\) liquid density kg/m³
\(H\) pump total head m
\(\Delta p\) pressure rise across the pump Pa
\(p_1\) pressure at the pump suction Pa
\(p_2\) pressure at the pump discharge Pa
\(H_p\) pressure head m
\(H_z\) static head m
\(H_f\) friction head m
\(g\) standard gravity, 9.806 65 m/s²

Method and standards

Energy balance between the liquid surfaces of the suction and discharge vessels, with total head as defined in ANSI/HI 1.6.

Where it is used

  • Specifying pumps for feed, transfer and cooling water.
  • Checking an existing pump against a new system.
  • Building system curves.

Common mistakes

  • Forgetting the pressure difference between suction and discharge vessels.
  • Using gauge and absolute pressures together.
  • Adding margin twice, on head and on flow.

Assumptions and limits

  • Liquid surfaces at rest; for a free discharge to atmosphere add the exit velocity head to the losses.
  • Losses at the design flow (use the pipe pressure drop calculator); the head at other flows follows the system curve.
  • Constant density.
  • Vapour pressure is not checked here: a positive suction pressure does not mean the pump is free of cavitation. Check the margin with the NPSH available calculator.

References

  • ANSI/HI 1.6 (total head definition)

Questions and answers

How do I calculate pump total head?

Add the pressure head between the vessels, the static height and all friction losses. A transfer pump from an open tank 2 m above it to an open tank 15 m up, with 3.5 m of losses, needs 13 + 3.5 = 16.5 m.

Why does a condensate pump need so much head?

It lifts water from a hot well under vacuum into a pressurised deaerator. From 0.12 bar(a) to 6 bar(a) the pressure head alone is 61 m.

Are velocity heads included?

Between two vessels the liquid surfaces are at rest, so the velocity heads cancel. Entry and exit losses belong in the friction losses.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.