Worked example
Example: BFW pump 900 m at 70 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Head at the operating point | 900.00 m |
| Pump efficiency at the operating point | 70.000 % |
| Specific heat of the liquid | 4.2300 kJ/(kg·K) |
| Flow at the operating point | 65.000 m³/h |
| Liquid density | 955.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Temperature rise through the pump | 0.89422 K |
| Loss energy per kg of liquid | 3.7826 kJ/kg |
| Heat put into the liquid | 65.223 kW |
Open this example in the calculator and change any input.
Formula
\(e = g\,H\left(\frac{1}{\eta} - 1\right) \qquad \Delta T = \frac{e}{c_p} \qquad P_{heat} = \rho\,Q\,e\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | head at the operating point | m |
| \(\eta\) | pump efficiency at the operating point | – |
| \(c_p\) | specific heat of the liquid | J/(kg·K) |
| \(Q\) | flow at the operating point | m³/s |
| \(\rho\) | liquid density | kg/m³ |
| \(\Delta T\) | temperature rise through the pump | K |
| \(e\) | loss energy per kg of liquid | J/kg |
| \(P_{heat}\) | heat put into the liquid | W |
| \(g\) | standard gravity, 9.806 65 | m/s² |
Method and standards
Energy balance on the pump: the shaft power not delivered as head (the losses) heats the liquid passing through, as given in Karassik's Pump Handbook. The specific heat is your input; the water values quoted in the help text are IAPWS-IF97 values. The calculator does not look up properties itself.
Where it is used
- Checking minimum flow of boiler feed pumps.
- Sizing recirculation lines.
- Low-flow running of hot-water pumps.
Common mistakes
- Running a feed pump below its minimum flow.
- Ignoring the margin to saturation at the pump.
- Using the efficiency at best efficiency point for low flow.
Assumptions and limits
- All losses go into the pumped liquid; bearing and seal losses and heat to the casing are neglected (conservative).
- The calculator does not compare ΔT with the margin to flashing: check that the suction temperature plus ΔT stays below the saturation temperature at the pump's internal pressure (use the NPSH available calculator for the suction margin).
- The minimum flow itself comes from the maker; this calculator checks the rise at a flow and efficiency you enter.
References
- Karassik et al.
- Pump Handbook (temperature rise); IAPWS-IF97 (source of the water c_p values quoted in the help text)
Questions and answers
How much does water warm up in a pump?
ΔT = g·H·(1 − η)/(η·c_p). A feed pump at 900 m and 70 % efficiency warms the water by only 0.9 K, but near minimum flow at 25 % efficiency and 1 000 m the rise is 7 K.
Why does it matter?
Feed water enters close to its boiling point. If the pump heats it enough at low flow it flashes inside the pump. A minimum-flow (recirculation) line keeps the flow, and so the efficiency, high enough.
Which efficiency should I use?
The pump's efficiency at the low flow you are checking, from the maker's curve. It falls steeply towards shut-off.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.