Pump Temperature Rise (Minimum Flow Check)

Temperature rise of the liquid through a pump from its head and efficiency, and the heat the losses put into the liquid: the check behind minimum-flow lines.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalIAPWS-IF97 (water and steam)BoilerPump

Inputs

Examples: BFW pump 900 m at 70 %BFW pump near minimum flow, 1 000 m at 25 %Water pump 50 m at 75 %

At low flow the efficiency falls steeply; read it from the maker's curve at that flow.
Water: 4.18 kJ/(kg·K) at 20 °C, 4.23 at 105 °C, 4.31 at 150 °C.

Results

Temperature rise through the pump6.9551K
Loss energy per kg of liquid29.420kJ/kg
Heat put into the liquid78.045kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: BFW pump 900 m at 70 %. The inputs, in the units selected above:

InputValue
Head at the operating point900.00 m
Pump efficiency at the operating point70.000 %
Specific heat of the liquid4.2300 kJ/(kg·K)
Flow at the operating point65.000 m³/h
Liquid density955.00 kg/m³

Applying the formula below gives:

ResultValue
Temperature rise through the pump0.89422 K
Loss energy per kg of liquid3.7826 kJ/kg
Heat put into the liquid65.223 kW

Open this example in the calculator and change any input.

Formula

\(e = g\,H\left(\frac{1}{\eta} - 1\right) \qquad \Delta T = \frac{e}{c_p} \qquad P_{heat} = \rho\,Q\,e\)

Variables

Symbol Meaning SI unit
\(H\) head at the operating point m
\(\eta\) pump efficiency at the operating point –
\(c_p\) specific heat of the liquid J/(kg·K)
\(Q\) flow at the operating point m³/s
\(\rho\) liquid density kg/m³
\(\Delta T\) temperature rise through the pump K
\(e\) loss energy per kg of liquid J/kg
\(P_{heat}\) heat put into the liquid W
\(g\) standard gravity, 9.806 65 m/s²

Method and standards

Energy balance on the pump: the shaft power not delivered as head (the losses) heats the liquid passing through, as given in Karassik's Pump Handbook. The specific heat is your input; the water values quoted in the help text are IAPWS-IF97 values. The calculator does not look up properties itself.

Where it is used

  • Checking minimum flow of boiler feed pumps.
  • Sizing recirculation lines.
  • Low-flow running of hot-water pumps.

Common mistakes

  • Running a feed pump below its minimum flow.
  • Ignoring the margin to saturation at the pump.
  • Using the efficiency at best efficiency point for low flow.

Assumptions and limits

  • All losses go into the pumped liquid; bearing and seal losses and heat to the casing are neglected (conservative).
  • The calculator does not compare ΔT with the margin to flashing: check that the suction temperature plus ΔT stays below the saturation temperature at the pump's internal pressure (use the NPSH available calculator for the suction margin).
  • The minimum flow itself comes from the maker; this calculator checks the rise at a flow and efficiency you enter.

References

  • Karassik et al.
  • Pump Handbook (temperature rise); IAPWS-IF97 (source of the water c_p values quoted in the help text)

Questions and answers

How much does water warm up in a pump?

ΔT = g·H·(1 − η)/(η·c_p). A feed pump at 900 m and 70 % efficiency warms the water by only 0.9 K, but near minimum flow at 25 % efficiency and 1 000 m the rise is 7 K.

Why does it matter?

Feed water enters close to its boiling point. If the pump heats it enough at low flow it flashes inside the pump. A minimum-flow (recirculation) line keeps the flow, and so the efficiency, high enough.

Which efficiency should I use?

The pump's efficiency at the low flow you are checking, from the maker's curve. It falls steeply towards shut-off.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.