Worked example
Example: Transfer pump 30 m³/h, 45 m, 68 %, +18 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Power absorbed from | Flow, head and efficiency |
| Flow | 30.000 m³/h |
| Total head | 45.000 m |
| Liquid density | 998.00 kg/m³ |
| Pump efficiency | 68.000 % |
| Pump shaft power (from the maker's data) | 0 kW |
| Motor margin over the power absorbed | 18.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Standard motor rating (IEC 60072-1) | 7.5000 kW |
| Minimum motor rating (absorbed + margin) | 6.3688 kW |
| Power absorbed at the pump shaft | 5.3973 kW |
| Hydraulic power | 3.6701 kW |
Open this example in the calculator and change any input.
Formula
\(P_h = \rho\,g\,Q\,H \qquad P_s = \frac{P_h}{\eta_p}\ \ \text{(or } P_{s,in}\text{ entered)} \qquad P_{m,min} = P_s\,(1 + m_m)\)
\(P_{std}\) is the smallest standard rating at or above \(P_{m,min}\).
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{basis}\) | power from flow and head, or shaft power entered | – |
| \(Q\) | flow | m³/s |
| \(H\) | total head | m |
| \(\rho\) | liquid density | kg/m³ |
| \(\eta_p\) | pump efficiency | – |
| \(P_{s,in}\) | shaft power from the maker's data | W |
| \(m_m\) | motor margin | – |
| \(P_{std}\) | standard motor rating | W |
| \(P_{m,min}\) | minimum motor rating | W |
| \(P_s\) | power absorbed at the pump shaft | W |
| \(P_h\) | hydraulic power | W |
| \(g\) | standard gravity, 9.806 65 | m/s² |
Method and standards
Power definitions of ANSI/HI 1.6; standard ratings of IEC 60072-1 (up to 1 000 kW) and the ISO 3 R20 preferred numbers above. The default efficiency (68 %) and motor margin (18 %) are FireCAD design practice (owner, 2026-11-10); both are inputs.
Where it is used
- Selecting feed, transfer and cooling water pump motors.
- Checking motor size after an impeller change.
- Specifying motors for purchase.
Common mistakes
- Sizing on duty point power when the pump can run out further on its curve.
- Adding margins twice.
- Ignoring cold-water starting for hot-water pumps.
Assumptions and limits
- Power at the duty point only; the end-of-curve power is not checked. For pumps that can run out to the end of their curve, check the power there too.
- Direct drive; divide by the coupling or gearbox efficiency first if there is one.
- Service factor, starting duty and ambient derating of the motor are not included.
References
- ANSI/HI 1.6 (power definitions)
- IEC 60072-1 (standard motor ratings)
Questions and answers
How do I select a motor for a pump?
Take the power absorbed at the duty, add the motor margin and choose the next standard rating. A pump for 30 m³/h at 45 m and 68 % absorbs 5.40 kW; with 18 % margin it needs 6.37 kW, so a 7.5 kW motor.
Why 18 %?
It is the FireCAD design-practice default for pump motors. Your specification, or the pump's end-of-curve power, may set a different margin; enter it.
Which standard ratings are used?
The IEC 60072-1 series (… 5.5, 7.5, 11, 15, 18.5, 22, 30, 37, 45, 55, 75, 90, 110 kW …) up to 1 000 kW, continued with the R20 preferred numbers above.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.