FireCADCalc

Pump Drive: Electric Motor or Back-Pressure Steam Turbine

Annual running cost of a pump driven by an electric motor or by a back-pressure steam turbine whose exhaust steam is used for process (Ganapathy Q5.08).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperSteam turbinePump

Inputs

Examples: Ganapathy: 230 gpm, 970 ft, 6000 hFeed pump 60 m3/h, 900 m

Results

Valid only if all the exhaust steam is used for process; if it is vented, charge the turbine's whole steam at boiler cost.

Pump shaft power195.94kW
Annual cost, motor drive148,500
Annual cost, steam turbine drive59,012
Annual saving with the turbine89,488

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 230 gpm, 970 ft, 6000 h. The inputs, in the units selected above:

InputValue
Flow52.239 m³/h
Head295.66 m
Liquid density999.00 kg/m³
Pump efficiency70.000 %
Motor efficiency90.000 %
Turbine mechanical efficiency95.000 %
Boiler efficiency (same GCV or NCV basis as the fuel price)85.000 %
Electricity price per kWh0.050000 -
Fuel price per GJ (same CV basis as the boiler efficiency)2.8435 -
Operating hours per year6,000.0 h

Applying the formula below gives:

ResultValue
Pump shaft power60.043 kW
Annual cost, motor drive20,014
Annual cost, steam turbine drive4,566.9
Annual saving with the turbine15,448

Open this example in the calculator and change any input.

Formula

\(P = \frac{\rho g Q H}{\eta_p}, \quad C_m = \frac{P}{\eta_m}\,t\,c_e, \quad C_t = \frac{P}{\eta_t\,\eta_b}\,t\,c_f\)

Variables

Symbol Meaning SI unit
\(Q\) Flow m³/s
\(H\) Head m
\(\rho\) Liquid density kg/m³
\(\eta_p\) Pump efficiency -
\(\eta_m\) Motor efficiency -
\(\eta_t\) Turbine mechanical efficiency -
\(\eta_b\) Boiler efficiency (same GCV or NCV basis as the fuel price) -
\(c_e\) Electricity price per kWh -
\(c_f\) Fuel price per GJ (same CV basis as the boiler efficiency) -
\(t\) Operating hours per year s
\(P\) Pump shaft power W
\(C_m\) Annual cost, motor drive -
\(C_t\) Annual cost, steam turbine drive -
\(C_m - C_t\) Annual saving with the turbine -

Method and standards

Ganapathy's comparison (back-pressure exhaust fully used).

Where it is used

  • Feed pump and fan drive selection in cogeneration plants.

Common mistakes

  • Ignoring that vented exhaust steam costs its full enthalpy.
  • Mixing currency units.

Assumptions and limits

  • Exhaust steam fully used for process.
  • Boiler efficiency and fuel price on one calorific-value basis (both GCV or both NCV).
  • Turbine steam rate, back-pressure, capital and maintenance costs are not modelled.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q5.08 (electric and steam turbine drives for pumps)

Questions and answers

Why is the turbine so cheap to run?

With the exhaust used for process, only the heat turned into shaft work is extra fuel: about 1/(η_t η_b) of the shaft energy.

What does Ganapathy's example give?

230 gpm at 970 ft: about $20,100 a year by motor against $4,600 by turbine.

What about capital cost?

Turbines, steam piping and governors cost more; compare payback.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.