Worked example
Example: 10 m³/h motive at 60 m, lifting 8 m³/h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Motive flow | 10.000 m³/h |
| Suction (entrained) flow | 8.0000 m³/h |
| Motive head at the nozzle | 60.000 m |
| Suction head | -2.0000 m |
| Discharge head | 10.000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flow ratio Q_s/Q_m | 0.80000 |
| Head ratio (H_d − H_s)/(H_m − H_d) | 0.24000 |
| Efficiency M·N | 19.200 % |
| Discharge flow | 18.000 m³/h |
Open this example in the calculator and change any input.
Formula
\(M = \frac{Q_s}{Q_m}, \quad N = \frac{H_d - H_s}{H_m - H_d}, \quad \eta = MN\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_m\) | Motive flow | m³/s |
| \(Q_s\) | Suction (entrained) flow | m³/s |
| \(H_m\) | Motive head at the nozzle | m |
| \(H_s\) | Suction head | m |
| \(H_d\) | Discharge head | m |
| \(M\) | Flow ratio Q_s/Q_m | - |
| \(N\) | Head ratio (H_d − H_s)/(H_m − H_d) | - |
| \(\eta\) | Efficiency M·N | - |
| \(Q_d\) | Discharge flow | m³/s |
Method and standards
Energy balance definitions.
Where it is used
- Tank mixing eductors.
- Sump and well jet pumps.
Common mistakes
- Using gauge pressures at different levels without converting to heads.
- Ignoring nozzle wear.
Assumptions and limits
- Same liquid; steady.
- H_m, H_s and H_d are total heads (pressure plus velocity head) at the motive inlet, suction and discharge connections, on one common datum.
- Efficiencies above 35 %, and above 100 %, are flagged.
References
- Jet pump head and flow ratios and efficiency η = MN (definitions; Karassik et al., Pump Handbook)
Questions and answers
Why so inefficient?
Mixing a fast jet with slow liquid destroys kinetic energy as turbulence; the best designs reach about a third.
Why use them?
No moving parts: tank mixing, priming, sump emptying, handling solids or corrosive liquids.
What do the defaults represent?
An eductor driven by 10 m³/h at 60 m head lifting 8 m³/h from 2 m below to a 10 m discharge.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.