Worked example
Example: 3 mm hole at 7 bar g. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Hole diameter | 3.0000 mm |
| Line pressure | 7.0000 bar g |
| Air temperature in the line | 30.000 °C |
| Discharge coefficient of the hole | 65.000 % |
| Isentropic exponent of air | 1.4000 - |
| Atmospheric pressure (absolute) | 101.33 kPa |
| Compressor inlet temperature | 30.000 °C |
| Compressor specific power (kW per m³/min of FAD) | 6.5000 - |
| Hours under pressure per year | 8,000.0 h |
| Energy price per kWh (your currency) | 8.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Leak as free air | 0.44036 m³/min |
| Leak mass flow | 30.766 kg/h |
| Compressor power wasted | 2.8624 kW |
| Energy wasted per year | 22,899 kWh |
| Cost per year (your currency) | 183,191 |
| Choked flow (1 = yes) | 1.0000 |
Open this example in the calculator and change any input.
Formula
\(\rho_0 = \frac{p_0 M}{R T_0} \qquad \dot m = C_d A \sqrt{k\,p_0\,\rho_0}\left(\frac{2}{k+1}\right)^{\frac{k+1}{2(k-1)}} \text{ (choked)}\)
\(\dot m = C_d A \sqrt{\frac{2k}{k-1}\,p_0\rho_0\left[r^{2/k} - r^{(k+1)/k}\right]},\ r = \frac{p_a}{p_0}\ \text{(not choked)}\) \(\dot V_a = \frac{\dot m}{\rho_a} \qquad P = \dot V_a\,SP \qquad E = P\,t_y \qquad C = E\,c_e\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d\) | hole diameter | m |
| \(p_0\) | line pressure | Pa |
| \(T_0\) | line temperature | K |
| \(C_d\) | discharge coefficient | – |
| \(k\) | isentropic exponent | – |
| \(p_a\) | atmospheric pressure | Pa |
| \(T_a\) | compressor inlet temperature | K |
| \(SP\) | specific power (P = V̇_a SP, with V̇_a in m³/min and SP in kW per m³/min) | kW per m³/min |
| \(t_y\) | hours per year | s |
| \(c_e\) | energy price | currency/kWh |
| \(\dot V_a\) | leak as free air | m³/s |
| \(\dot m\) | mass flow | kg/s |
| \(P\) | power wasted | W |
| \(E\) | energy per year | J |
| \(C\) | cost per year | currency |
| \(\text{choked}\) | choked flow flag | – |
| \(r\) | pressure ratio p_a/p_0 | – |
| \(A\) | hole area | m² |
| \(\rho_0, \rho_a\) | line and inlet air density | kg/m³ |
Method and standards
Isentropic nozzle flow of an ideal gas (dry air of the PTC 4 composition), choked below the critical pressure ratio, else the subsonic form.
Where it is used
- Leak surveys and tagging.
- Justifying leak repair programmes.
- Compressed-air energy audits.
Common mistakes
- Using Cd of 1 for ragged holes.
- Counting hours when the system is depressurised.
- Forgetting that leaks also force extra compressors to run.
Assumptions and limits
- Dry air; round hole; no pipe friction upstream.
- A line pressure entered as gauge is turned into absolute with the standard atmosphere, not the site p_a; at altitude enter it as absolute (a note appears when p_a differs from 1.01325 bar).
References
- Isentropic nozzle flow of an ideal gas
Questions and answers
What does a 3 mm leak at 7 bar g cost?
About 0.44 m³/min of free air, 2.9 kW of compressor power and 22 900 kWh a year at 8000 h: 183 000 a year at 8 per kWh.
Why is the flow choked?
Above about 0.9 bar g the leak reaches sonic speed in the hole; flow then rises in step with line pressure.
Which specific power?
Your compressor's kW per m³/min from the data sheet or an audit.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.