FireCADCalc

Induction Coil Electrical Efficiency (Cylinder or Slab)

Electrical efficiency of a solenoid induction coil heating a cylinder or slab from coil and workpiece sizes, resistivities, permeability and frequency.

Inputs

Examples: Steel bar above Curie, 100 mm in 140 mm coil, 1 kHzCopper billet 100 mm in 140 mm coil, 500 HzSteel slab above Curie, perimeters 2.4 and 1.9 m, 500 Hz

Accepted: 5 to 3,000 mm
Accepted: 2 to 3,000 mm
Accepted: 10 to 20,000 mm
Accepted: 10 to 20,000 mm
Accepted: 0.001 to 1 Ω·mm²/m
Accepted: 0.001 to 100 Ω·mm²/m
Accepted: 1 to 2,000
Accepted: 1 to 1,000,000 Hz

Results

Long single-layer solenoid, pronounced skin effect, no other conductive parts nearby. Smaller coil-to-workpiece gaps and magnetic or high-resistivity loads give high efficiency.

Reference depth in the coil copper2.2508mm
Reference depth in the workpiece17.435mm
Coil electrical efficiency factor0.22242
Coil electrical efficiency81.805%
Workpiece size to reference depth (cylinder)5.7357

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Steel bar above Curie, 100 mm in 140 mm coil, 1 kHz. The inputs, in the units selected above:

InputValue
Workpiece shapeSolid cylinder in a round coil
Coil inside diameter (cylinder)140.00 mm
Workpiece diameter (cylinder)100.00 mm
Perimeter of the coil opening (slab)1,200.0 mm
Perimeter of the slab (slab)900.00 mm
Resistivity of the coil copper (at its temperature)0.020000 Ω·mm²/m
Resistivity of the workpiece (at its temperature)1.2000 Ω·mm²/m
Relative permeability of the workpiece1.0000 -
Frequency1,000.0 Hz

Applying the formula below gives:

ResultValue
Reference depth in the coil copper2.2508 mm
Reference depth in the workpiece17.435 mm
Coil electrical efficiency factor0.22242
Coil electrical efficiency81.805 %
Workpiece size to reference depth (cylinder)5.7357

Open this example in the calculator and change any input.

Formula

\(\eta_{el} = \frac{1}{1 + \frac{D_1'}{D_2'}\sqrt{\frac{\rho_1}{\mu_r\rho_2}}}, \quad D_1' = D_1 + \delta_1, \quad D_2' = D_2 - \delta_2, \quad \delta = \sqrt{\frac{\rho}{\pi f\mu_0\mu_r}}; \quad \text{slab: } \eta_{el} = \frac{1}{1 + \frac{F_1}{F_2}\sqrt{\frac{\rho_1}{\mu_r\rho_2}}}\)

Variables

Symbol Meaning SI unit
\(\text{load}\) Workpiece shape -
\(D_1\) Coil inside diameter (cylinder) m
\(D_2\) Workpiece diameter (cylinder) m
\(F_1\) Perimeter of the coil opening (slab) m
\(F_2\) Perimeter of the slab (slab) m
\(\rho_1\) Resistivity of the coil copper (at its temperature) Ω·m
\(\rho_2\) Resistivity of the workpiece (at its temperature) Ω·m
\(\mu_r\) Relative permeability of the workpiece -
\(f\) Frequency 1/s
\(\delta_1\) Reference depth in the coil copper m
\(\delta_2\) Reference depth in the workpiece m
\(\text{factor}\) Coil electrical efficiency factor -
\(\eta_{el}\) Coil electrical efficiency -
\(D_2/\delta_2\) Workpiece size to reference depth (cylinder) -

Method and standards

Electrical efficiency of a long solenoid coil.

Where it is used

  • Coil design for billet, bar and slab heaters.
  • Judging the effect of air gap and refractory.

Common mistakes

  • Using cold resistivities for hot workpieces.
  • Ignoring the drop in μ_r above the Curie point.

Assumptions and limits

  • Long single-layer coil; pronounced skin effect.

Questions and answers

Why does a refractory lining lower electrical efficiency?

It widens the coil-to-workpiece gap, so D₁′/D₂′ rises; the lining is still worth it when it cuts heat losses more than it costs in coupling.

Why is steel efficient below the Curie point?

Its relative permeability is in the hundreds, so the workpiece takes far more of the power than the copper coil.

What do the defaults represent?

A 100 mm steel bar above the Curie point (1.2 μΩ·m, μ_r = 1) in a 140 mm coil at 1 kHz, coil copper at 2.0 × 10⁻⁸ Ω·m.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Rudnev, Loveless, Cook and Black, Handbook of Induction Heating (Marcel Dekker, 2003), sec. 3.3.1, eqs. 3.25 and 3.26

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.