Worked example
Example: Illustrative 150 t/h walking beam. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Throughput | 150.00 t/h |
| Effective hearth length | 30.000 m |
| Effective hearth width | 12.000 m |
| Stock thickness | 220.00 mm |
| Hearth coverage | 85.000 % |
| Steel density | 7,850.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steel on the hearth | 528.46 t |
| Residence time | 3.5231 h |
| Hearth rating | 416.67 kg/(m²·h) |
| Hearth area | 360.00 m² |
Open this example in the calculator and change any input.
Formula
\(m_h = LWft\rho, \quad t_r = \frac{m_h}{\dot m}, \quad \frac{\dot m}{A} = \frac{\dot m}{LW}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Throughput | kg/s |
| \(L\) | Effective hearth length | m |
| \(W\) | Effective hearth width | m |
| \(t\) | Stock thickness | m |
| \(f\) | Hearth coverage | - |
| \(\rho\) | Steel density | kg/m³ |
| \(m_h\) | Steel on the hearth | kg |
| \(t_r\) | Residence time | s |
| \(\dot m/A\) | Hearth rating | kg/(m²·s) |
| \(A\) | Hearth area | m² |
Method and standards
Hearth loading.
Where it is used
- Rolling mill furnace capacity checks.
- Changing stock sizes and rates.
Common mistakes
- Counting the hearth length of the soak zone only.
- Forgetting gaps between pieces (coverage).
Assumptions and limits
- Uniform stock and coverage along the hearth.
References
- Reheating furnace inventory relations
Questions and answers
Why is residence time tied to thickness?
Heat must conduct to the centre; heating time grows with thickness (and with its square for one-sided heating).
What limits throughput?
Hearth area times permissible rating, set by heating time, scale formation and burner capacity.
What do the defaults represent?
An illustrative 150 t/h walking-beam furnace with a 30 × 12 m hearth, 220 mm slabs at 85 % coverage.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Trinks, Mawhinney, Shannon, Reed and Garvey, Industrial Furnaces, 6th ed. (Wiley, 2004)