Radiant Tube Heater Output to the Load

Radiant heat from gas- or electric-fired radiant tubes to a furnace load, from tube size, number, temperatures and emissivities, as a two-surface enclosure.

Inputs

Examples: Illustrative ten tubes at 950 CCold load at startElectric tubes, annealing

Accepted: 20 to 500 mm
Accepted: 0.2 to 10 m
Accepted: 1 to 500
Accepted: 300 to 1,200 °C
Accepted: 0 to 1,200 °C
Accepted: 10 to 100 %
Accepted: 10 to 100 %
Accepted: 0.01 to 1

Results

Radiant tubes keep combustion gases away from the load (for controlled-atmosphere heat treatment). Treating the tubes and the load as a two-surface enclosure with reradiating walls lumped in, the exchange factor is 1/(1/ε_t + (A_t/A_l)(1/ε_l − 1)). The rating falls sharply as the load approaches tube temperature, so heating time is set by the final soak. Tube life limits surface temperature (about 950–1050 °C for heat-resisting alloys).

Tube surface area9.4248m²
Exchange factor0.78341
Heat to the load381.83kW
Flux on the tube40.513kW/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative ten tubes at 950 C. The inputs, in the units selected above:

InputValue
Tube outside diameter150.00 mm
Heated tube length2.0000 m
Number of tubes10.000 -
Tube surface temperature950.00 °C
Load surface temperature800.00 °C
Tube emissivity85.000 %
Load emissivity80.000 %
Tube area over load area0.40000 -

Applying the formula below gives:

ResultValue
Tube surface area9.4248 m²
Exchange factor0.78341
Heat to the load381.83 kW
Flux on the tube40.513 kW/m²

Open this example in the calculator and change any input.

Formula

\(Q = \sigma A_t F\left(T_t^4 - T_l^4\right), \quad F = \frac{1}{1/\varepsilon_t + (A_t/A_l)(1/\varepsilon_l - 1)}\)

Variables

Symbol Meaning SI unit
\(d\) Tube outside diameter m
\(L\) Heated tube length m
\(n\) Number of tubes -
\(T_t\) Tube surface temperature K
\(T_l\) Load surface temperature K
\(\varepsilon_t\) Tube emissivity -
\(\varepsilon_l\) Load emissivity -
\(A_t/A_l\) Tube area over load area -
\(A_t\) Tube surface area m²
\(F\) Exchange factor -
\(Q\) Heat to the load W
\(q\) Flux on the tube W/m²

Method and standards

Radiant tubes.

Where it is used

  • Heat treatment and annealing furnaces.
  • Converting direct-fired to indirect heating.

Common mistakes

  • Using gas temperature for tube temperature.
  • Ignoring tube life limits.

Assumptions and limits

  • Gray surfaces; reradiating walls.

References

  • Two-surface gray enclosure radiation

Questions and answers

How much heat do ten 150 mm × 2 m tubes at 950 °C give to a load at 800 °C?

About 380 kW, near 40 kW/m² of tube surface.

Why does the output fall as the load heats?

Radiation depends on the difference of fourth powers of temperature.

What do the defaults represent?

Ten 150 mm tubes, 2 m heated length, at 950 °C, radiating to a load at 800 °C, emissivities 0.85 and 0.8, area ratio 0.4.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.