Worked example
Example: Illustrative 230 mm firebrick. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wall area | 80.000 m² |
| Lining thickness | 230.00 mm |
| Lining density | 2,000.0 kg/m³ |
| Lining specific heat | 1.0000 kJ/(kg·K) |
| Lining conductivity | 1.1000 W/(m·K) |
| Hot face temperature | 1,000.0 °C |
| Cold face temperature | 100.00 °C |
| Initial (ambient) temperature | 30.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat stored in the wall | 19,136 MJ |
| Steady conduction loss | 344.35 kW |
| Storage equal to hours of steady loss | 15.437 h |
| Lining mass | 36.800 t |
Open this example in the calculator and change any input.
Formula
\(Q_s = \rho cAL\left(\frac{T_h + T_c}{2} - T_0\right), \quad \dot Q_l = \frac{kA(T_h - T_c)}{L}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Wall area | m² |
| \(L\) | Lining thickness | m |
| \(\rho\) | Lining density | kg/m³ |
| \(c\) | Lining specific heat | J/(kg·K) |
| \(k\) | Lining conductivity | W/(m·K) |
| \(T_h\) | Hot face temperature | K |
| \(T_c\) | Cold face temperature | K |
| \(T_0\) | Initial (ambient) temperature | K |
| \(Q_s\) | Heat stored in the wall | J |
| \(\dot Q_l\) | Steady conduction loss | W |
| \(Q_s/\dot Q_l\) | Storage equal to hours of steady loss | s |
| \(m\) | Lining mass | kg |
Method and standards
Wall storage.
Where it is used
- Batch and intermittent furnace design.
- Lining replacement studies.
Common mistakes
- Comparing linings only by steady loss.
- Ignoring storage when estimating cycle fuel.
Assumptions and limits
- Single uniform layer at steady state.
References
- Stored and conducted heat of a furnace wall
Questions and answers
Why does lining choice matter for batch furnaces?
Every cycle the lining must be reheated; heavy brick may store more heat than the load receives.
Why use the mean of hot and cold faces?
At steady state the temperature falls linearly through a uniform wall, so the mean equals the average of the faces.
What do the defaults represent?
An illustrative 80 m² of 230 mm firebrick (2,000 kg/m³) at 1,000 °C hot face and 100 °C cold face.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Trinks, Mawhinney, Shannon, Reed and Garvey, Industrial Furnaces, 6th ed. (Wiley, 2004)