Worked example
Example: Trinks: 1800 F exit, 10 % excess air, 800 F air against 60 F. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Methane in the fuel gas | 90.000 % |
| Ethane | 5.0000 % |
| Propane | 1.0000 % |
| Nitrogen | 4.0000 % |
| Excess air | 10.000 % |
| Flue gas exit temperature from the furnace | 982.22 °C |
| Combustion air temperature (preheated) | 426.67 °C |
| Air temperature of the base case | 15.556 °C |
| Heat needed by the load plus furnace losses | 2,000.0 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Available heat with preheated air (gross basis) | 62.183 % |
| Available heat of the base case | 47.690 % |
| Fuel saved against the base case | 23.307 % |
| Gross fuel input with preheat | 3,216.3 kW |
| Gross fuel input in the base case | 4,193.8 kW |
| Fuel gas flow with preheat | 287.80 Nm³/h |
| Gross calorific value of the gas | 40.232 MJ/Nm³ |
Open this example in the calculator and change any input.
Formula
\(AH = \frac{GCV - \Delta H_{flue}(T_{ex}) - n_{H_2O}L_{25} + \Delta H_{air}(T_a)}{GCV}, \quad \text{saving} = 1 - \frac{AH_0}{AH}, \quad Q_{in} = \frac{Q}{AH}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(y_{CH_4}\) | Methane in the fuel gas | - |
| \(y_{C_2H_6}\) | Ethane | - |
| \(y_{C_3H_8}\) | Propane | - |
| \(y_{N_2}\) | Nitrogen | - |
| \(EA\) | Excess air | - |
| \(T_{ex}\) | Flue gas exit temperature from the furnace | K |
| \(T_a\) | Combustion air temperature (preheated) | K |
| \(T_0\) | Air temperature of the base case | K |
| \(Q\) | Heat needed by the load plus furnace losses | W |
| \(AH\) | Available heat with preheated air (gross basis) | - |
| \(AH_0\) | Available heat of the base case | - |
| \(1 - AH_0/AH\) | Fuel saved against the base case | - |
| \(Q/AH\) | Gross fuel input with preheat | W |
| \(Q/AH_0\) | Gross fuel input in the base case | W |
| \(\dot V_f\) | Fuel gas flow with preheat | Nm³/s |
| \(GCV\) | Gross calorific value of the gas | J/m³ |
Method and standards
Available-heat balance on the gross basis.
Where it is used
- Reheat, forge and heat-treatment furnaces.
- Justifying recuperators and regenerative burners.
Common mistakes
- Using the stack temperature after the recuperator as the exit temperature.
- Mixing gross and net bases.
Assumptions and limits
- Complete combustion; dry air.
References
- Trinks
- Mawhinney
- Shannon
- Reed and Garvey
- Industrial Furnaces
- 6th ed. (Wiley, 2004)
- ch. 5 (available heat, fuel saving by air preheat, Example 5.3)
- NIST Shomate gas enthalpies and IAPWS-IF97 latent heat (engine)
Questions and answers
What is available heat?
The part of the fuel's gross heat left in the furnace after the flue gas leaves at its exit temperature; at 1,800 °F with cold air only about half of natural gas heat is available.
Why does preheating save so much fuel in hot furnaces?
The air brings back heat that would otherwise leave in the flue; Trinks's natural gas at 1,800 °F goes from 48 % to 62 % available heat with 800 °F air.
What do the defaults represent?
Trinks's natural gas (90 % CH₄, 5 % C₂H₆, 1 % C₃H₈, 4 % N₂) at 1,800 °F exit and 10 % excess air, with 800 °F against 60 °F air, for 2 MW of heat needed.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.