Worked example
Example: Illustrative 5 t/h steel melt. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Melt rate | 5.0000 t/h |
| Mean specific heat of the solid | 0.68000 kJ/(kg·K) |
| Charge temperature | 25.000 °C |
| Melting temperature | 1,500.0 °C |
| Latent heat of fusion | 270.00 kJ/kg |
| Specific heat of the liquid | 0.82000 kJ/(kg·K) |
| Tapping temperature | 1,600.0 °C |
| Overall efficiency (electrical × thermal) | 70.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat into the metal per tonne | 376.39 kWh/t |
| Heat rate into the metal | 1,881.9 kW |
| Electrical power | 2,688.5 kW |
| Electrical energy per tonne | 537.70 kWh/t |
Open this example in the calculator and change any input.
Formula
\(q = \bar c_s(T_m - T_0) + L_f + c_l(T_t - T_m), \quad P_e = \frac{\dot mq}{\eta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Melt rate | kg/s |
| \(\bar c_s\) | Mean specific heat of the solid | J/(kg·K) |
| \(T_0\) | Charge temperature | K |
| \(T_m\) | Melting temperature | K |
| \(L_f\) | Latent heat of fusion | J/kg |
| \(c_l\) | Specific heat of the liquid | J/(kg·K) |
| \(T_t\) | Tapping temperature | K |
| \(\eta\) | Overall efficiency (electrical × thermal) | - |
| \(q\) | Heat into the metal per tonne | J/kg |
| \(P_m\) | Heat rate into the metal | W |
| \(P_e\) | Electrical power | W |
| \(q_e\) | Electrical energy per tonne | J/kg |
Method and standards
Melting energy.
Where it is used
- Sizing induction furnaces and power supplies.
- Benchmarking foundry energy use.
Common mistakes
- Forgetting superheat and holding.
- Using the liquid specific heat for the solid range.
Assumptions and limits
- Steady melt rate; mean properties; losses lumped in the efficiency.
References
- Heat balance of a melting furnace
Questions and answers
Why is the meter energy so much higher than the metal's heat?
Coil I²R losses, cooling water, refractory and radiation losses and holding time all draw power.
What mean specific heat should I use for steel?
About 0.65–0.70 kJ/kg·K from room temperature to the melting point, which includes the phase changes in the solid.
What do the defaults represent?
An illustrative 5 t/h steel melt from 25 °C, melting at 1,500 °C, tapped at 1,600 °C, 70 % overall efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Rudnev, Loveless and Cook, Handbook of Induction Heating, 2nd ed. (CRC Press, 2017)