FireCADCalc

Electric Arc Furnace Energy per Tonne and Power-On Time

Heat to melt and superheat steel and slag in an arc furnace, less chemical energy, as electricity per tonne for an efficiency, and the power-on time.

Inputs

Examples: Illustrative 120 t scrap EAFHot heel, more oxygenSmall foundry arc furnace

Accepted: 1,499.8 to 1,749.8 °C
Accepted: 1,399.8 to 1,549.8 °C
Accepted: 0.5 to 0.8 kJ/(kg·K)
Accepted: 200 to 300 kJ/kg
Accepted: 0.7 to 0.9 kJ/(kg·K)
Accepted: 0 to 300 kg/t
Accepted: 1 to 3 MJ/kg
Accepted: 0 to 2,000 kJ/kg
Accepted: 40 to 95 %
Accepted: 1 to 300 MW
Accepted: 1 to 400 t
Accepted: -10.15 to 999.85 °C

Results

Steel heat = c_s(T_m − T₀) + L_f + c_l(T_tap − T_m), about 380–400 kWh/t at 1,640 °C; add slag heat, subtract chemical energy from oxygen and burners, divide by the electrical efficiency to the bath. Modern scrap furnaces use about 350–450 kWh/t of electricity; hot metal, DRI and preheated scrap change this a lot.

Heat in liquid steel384.72kWh/t
Heat in slag66.667kWh/t
Electrical energy406.75kWh/t
Power-on time36.607min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 120 t scrap EAF. The inputs, in the units selected above:

InputValue
Tapping temperature1,640.0 °C
Melting temperature1,520.0 °C
Mean specific heat of solid steel0.68000 kJ/(kg·K)
Latent heat of fusion270.00 kJ/kg
Specific heat of liquid steel0.82000 kJ/(kg·K)
Slag per tonne of steel120.00 kg/t
Slag heat content2.0000 MJ/kg
Chemical energy (oxygen, fuel) per tonne600.00 kJ/kg
Electrical-to-bath efficiency70.000 %
Active power to the arc80.000 MW
Tap weight120.00 t
Charge temperature25.000 °C

Applying the formula below gives:

ResultValue
Heat in liquid steel384.72 kWh/t
Heat in slag66.667 kWh/t
Electrical energy406.75 kWh/t
Power-on time36.607 min

Open this example in the calculator and change any input.

Formula

\(h_{st} = c_s(T_m - T_0) + L_f + c_l(T_{tap} - T_m), \quad e_{el} = \frac{h_{st} + m_{sl}h_{sl} - q_{chem}}{\eta_e}, \quad t_{on} = \frac{e_{el}m_{tap}}{P}\)

Variables

Symbol Meaning SI unit
\(T_{tap}\) Tapping temperature K
\(T_m\) Melting temperature K
\(c_s\) Mean specific heat of solid steel J/(kg·K)
\(L_f\) Latent heat of fusion J/kg
\(c_l\) Specific heat of liquid steel J/(kg·K)
\(m_{sl}\) Slag per tonne of steel kg/kg
\(h_{sl}\) Slag heat content J/kg
\(q_{chem}\) Chemical energy (oxygen, fuel) per tonne J/kg
\(\eta_e\) Electrical-to-bath efficiency -
\(P\) Active power to the arc W
\(m_{tap}\) Tap weight kg
\(T_0\) Charge temperature K
\(h_{st}\) Heat in liquid steel J/kg
\(e_{el}\) Electrical energy J/kg
\(t_{on}\) Power-on time s

Method and standards

EAF energy.

Where it is used

  • EAF and induction melting budgets.
  • Comparing charge mixes.

Common mistakes

  • Mixing kWh/t of steel and of charge.
  • Ignoring slag heat.

Assumptions and limits

  • Mean properties; losses lumped in the efficiency.

References

  • EAF energy balance

Questions and answers

How much energy does melting steel need?

About 380–400 kWh/t to melt and superheat scrap to tapping temperature, before losses.

Why add chemical energy?

Oxygen lancing oxidises carbon, iron and other elements and burners add fuel heat, replacing part of the electricity.

What do the defaults represent?

An illustrative 120 t scrap EAF tapping at 1,640 °C with 120 kg/t slag, 0.6 GJ/t chemical energy, 70 % electrical efficiency and 80 MW arc power.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

AISE, The Making, Shaping and Treating of Steel, 11th ed. (AISE Steel Foundation, 1998)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.