Worked example
Example: Illustrative 100 mm bar to 850 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Section shape | Long round bar |
| Half-thickness or radius | 50.000 mm |
| Thermal conductivity | 30.000 W/(m·K) |
| Density | 7,850.0 kg/m³ |
| Specific heat (mean) | 0.60000 kJ/(kg·K) |
| Initial temperature | 30.000 °C |
| Furnace temperature | 850.00 °C |
| Allowed centre lag behind furnace | 10.000 K |
| Convective coefficient | 15.000 W/(m²·K) |
| Surface emissivity | 80.000 % |
| Metallurgical soak time at temperature | 30.000 min |
Applying the formula below gives:
| Result | Value |
|---|---|
| Combined surface coefficient | 270.37 W/(m²·K) |
| Biot number | 0.45062 |
| Fourier number at the end of heating | 5.5825 |
| Heating time | 36.519 min |
| Heating plus soak | 66.519 min |
Open this example in the calculator and change any input.
Formula
\(\frac{T_f - T_c}{T_f - T_i} = C_1e^{-\lambda_1^2Fo}, \quad t_h = \frac{Fo\,L^2\rho c_p}{k}, \quad h = h_c + \varepsilon\sigma(T_f^2 + T_s^2)(T_f + T_s)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{shape}\) | Section shape | - |
| \(L\) | Half-thickness or radius | m |
| \(k\) | Thermal conductivity | W/(m·K) |
| \(\rho\) | Density | kg/m³ |
| \(c_p\) | Specific heat (mean) | J/(kg·K) |
| \(T_i\) | Initial temperature | K |
| \(T_f\) | Furnace temperature | K |
| \(\Delta T_c\) | Allowed centre lag behind furnace | K |
| \(h_c\) | Convective coefficient | W/(m²·K) |
| \(\varepsilon\) | Surface emissivity | - |
| \(t_s\) | Metallurgical soak time at temperature | s |
| \(h\) | Combined surface coefficient | W/(m²·K) |
| \(Bi\) | Biot number | - |
| \(Fo\) | Fourier number at the end of heating | - |
| \(t_h\) | Heating time | s |
| \(t\) | Heating plus soak | s |
Method and standards
Heating time.
Where it is used
- Planning hardening, normalising and stress-relief cycles.
- Furnace loading schedules.
Common mistakes
- Starting soak timing when the furnace, not the part, reaches temperature.
- Ignoring shading of parts in dense loads.
Assumptions and limits
- Constant properties and h; isolated part; one-term solution.
References
- One-term transient conduction with linearised radiation
Questions and answers
Why not just use one hour per inch?
The rule ignores furnace temperature, emissivity and material; this calculation shows where it is generous or short.
What is the soak time for?
Time at temperature for the metallurgical change itself, such as dissolving carbides before hardening, after the centre has arrived.
What do the defaults represent?
An illustrative 100 mm steel bar heated from 30 °C in an 850 °C furnace to within 10 K at the centre, emissivity 0.8, h_c 15, then soaked 30 minutes.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Incropera and DeWitt, Fundamentals of Heat and Mass Transfer, 6th ed. (Wiley, 2007), Trinks, Mawhinney, Shannon, Reed and Garvey, Industrial Furnaces, 6th ed. (Wiley, 2004)