Worked example
Example: Hot steel at 10 kHz, 2 mm target. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Resistivity of the hot workpiece | 1.2000 Ω·mm²/m |
| Relative permeability | 1.0000 - |
| Frequency | 10.000 kHz |
| Desired reference depth | 2.0000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reference depth at f | 5.5133 mm |
| Frequency for the desired depth | 75.991 kHz |
| Share of power within δ (1 − e⁻², always 86.5 %) | 86.466 % |
Open this example in the calculator and change any input.
Formula
\(\delta = \sqrt{\frac{\rho}{\pi f\mu_0\mu_r}}, \quad f_t = \frac{\rho}{\pi\mu_0\mu_r\delta_t^2}, \quad P_\delta = 1 - e^{-2} \approx 86.5\ \%\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho\) | Resistivity of the hot workpiece | Ω·m |
| \(\mu_r\) | Relative permeability | - |
| \(f\) | Frequency | 1/s |
| \(\delta_t\) | Desired reference depth | m |
| \(\delta\) | Reference depth at f | m |
| \(f_t\) | Frequency for the desired depth | 1/s |
| \(P_\delta\) | Share of power within δ | - |
Method and standards
Electromagnetic penetration depth.
Where it is used
- Induction hardening of shafts and gears.
- Induction heating for forging and brazing.
Common mistakes
- Using cold properties for the hot surface.
- Expecting the case depth to equal δ exactly.
Assumptions and limits
- Flat-surface approximation (radius ≫ δ). The share of power within δ is the constant 1 − e⁻² for this exponential decay, shown for reference.
References
- Reference depth δ = √(ρ/(πfμ₀μ_r)) (Rudnev et al., Handbook of Induction Heating, ch. 3)
Questions and answers
Why higher frequency for shallow cases?
Reference depth falls with the square root of frequency: four times the frequency halves the depth.
Why does depth change during heating?
Below the Curie point steel is magnetic (μ_r up to hundreds); above it μ_r = 1 and resistivity rises, so δ grows tenfold.
What do the defaults represent?
Steel above the Curie point at 10 kHz, with a 2 mm target depth.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.