Worked example
Example: Illustrative 530 C for 40 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Case growth constant at the reference temperature (mm/√h) | 0.070000 - |
| Reference temperature | 510.00 °C |
| Activation energy | 140.00 kJ/mol |
| Process temperature | 530.00 °C |
| Nitriding time | 40.000 h |
| Target case depth | 0.50000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Growth constant at process temperature (mm/√h) | 0.091487 |
| Case depth after the time | 0.57862 mm |
| Time for the target depth | 29.869 h |
Open this example in the calculator and change any input.
Formula
\(d = k\sqrt t, \quad k = k_{ref}\exp\left[-\frac{Q}{2R}\left(\frac1T - \frac1{T_{ref}}\right)\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k_{ref}\) | Case growth constant at the reference temperature (mm/√h) | - |
| \(T_{ref}\) | Reference temperature | K |
| \(Q\) | Activation energy | J/mol |
| \(T\) | Process temperature | K |
| \(t\) | Nitriding time | s |
| \(d_t\) | Target case depth | m |
| \(k\) | Growth constant at process temperature (mm/√h) | - |
| \(d\) | Case depth after the time | m |
| \(t_t\) | Time for the target depth | s |
Method and standards
Parabolic growth.
Where it is used
- Nitriding cycle planning.
- Comparing process temperatures.
Common mistakes
- Using carburising constants for nitriding.
- Expecting linear growth with time.
Assumptions and limits
- Diffusion-controlled growth.
References
- Parabolic case growth with Arrhenius temperature dependence
Questions and answers
Why does nitriding take so long?
It runs at 500–550 °C, well below carburising temperatures, so nitrogen diffuses slowly; 0.5 mm cases often take 40–80 hours.
Why not just raise the temperature?
Higher temperature speeds diffusion but softens the core and coarsens nitrides, lowering surface hardness.
What do the defaults represent?
An illustrative gas nitriding constant of 0.07 mm/√h at 510 °C, run at 530 °C for 40 hours, target 0.5 mm.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Callister and Rethwisch, Materials Science and Engineering, 9th ed. (Wiley, 2014), ch. 5